NAPCO GEM-P1664EX Programming Instructions Manual
Hide thumbs Also See for GEM-P1664EX:
Table of Contents

Advertisement

Quick Links

R
HARDWIRE
CONTROL PANEL/COMMUNICATOR
"Classic" GEM-RP2ASe2, GEM-RP3DGTL, and GEM-RP4RFC/GEM-RP4C Keypads and
the "K Series" GEM-K2AS, GEM-K3DGTL, and GEM-K4/GEM-K4RF Keypads
GEMINI
SYSTEM ARMED
01/01/97 12:00AM
A
1 2
R
B
4
5 6
C
7 8 9 0
COMPUTERIZED SECURITY SYSTEM
"K Series" GEM-K2AS
Quick Start (for GEM-K2AS):
1.
Refer to the wiring diagram, connect Siren, Aux. Power,
PGM Output, Remote Bus, Earth Ground, Zone and Tele-
phone Wiring. NOTE: See Installation Instructions (WI1388).
2.
Connect AC power first and then the battery.
3.
Configure the keypad (see page 55).
4.
Access the Easy Menu Driven (Dealer Program) Mode:
Press
456789
Dealer Code
Press NO until "TURNON PROG Y/N" appears on the keypad display.
Press NEXT/YES to enter Dealer Program Mode. See page 5.
© NAPCO 2005
Publicly traded on NASDAQ
G E M - P 1 6 6 4 E X
Programming the GEM-P1664EX Control Panel with the
"K Series" GEM-K4/GEM-K4RF
READY
READY
AC ON
AC ON
NEXT/YES
3
E
D
PRIOR/NO
F
AREA
G
R
R
Symbol: NSSC
PROGRAMMING
INSTRUCTIONS
WIRELESS
GEMINI
SYSTEM ARMED
32
01/01/97 12:00AM
INTERIOR
A
1 2
R
B
4
5 6
C
7 8 9 0
COMPUTERIZED SECURITY SYSTEM
"K Series" GEM-K3DGTL
Quick Start (for GEM-K3DGTL):
1.
Refer to the wiring diagram, connect Siren, Aux. Power,
PGM Output, Remote Bus, Earth Ground, Zone and Tele-
phone Wiring. NOTE: See Installation Instructions (WI1388).
2.
Connect AC power first and then the battery.
3.
Configure the keypad (see page 55).
4.
Access the Easy Menu Driven (Dealer Program) Mode:
Press
456789
Dealer Code
Press NO until "17" appears on the keypad display.
Press NEXT/YES to enter Dealer Program Mode. See page 5.
ENT A1
BYPASS
FIRE/TBL
SYS TBL
CHIME
NEXT/YES
3
E
D
PRIOR/NO
F
AREA
G
R
R
WI1387 7/05

Advertisement

Table of Contents
loading

Summary of Contents for NAPCO GEM-P1664EX

  • Page 1 HARDWIRE WIRELESS G E M - P 1 6 6 4 E X CONTROL PANEL/COMMUNICATOR Programming the GEM-P1664EX Control Panel with the "Classic" GEM-RP2ASe2, GEM-RP3DGTL, and GEM-RP4RFC/GEM-RP4C Keypads and the "K Series" GEM-K2AS, GEM-K3DGTL, and GEM-K4/GEM-K4RF Keypads "K Series" GEM-K4/GEM-K4RF...
  • Page 2 CONTROL PANEL FIRMWARE VERSION 01 OR LATER. IMPORTANT NOTE This manual supports the keypad programming of the GEM-P1664EX control panel with the NAPCO "classic" GEM- RP2ASe2, GEM-RP3DGTL and GEM-RP4RFC series keypads as well as the GEM-K2AS, GEM-K3DGTL and GEM- K4RF "K Series" keypads. The new "K Series" models offer the new STAY and AWAY buttons with simplified function- ality, along with the new MENU and ENTER buttons.
  • Page 3: Table Of Contents

    EXPERIENCE AND INSTALLATION EQUIPMENT. THE UNIT IS DESIGNED TO BE PROGRAMMED USING AN IBM-COMPATIBLE COMPUTER WITH NAPCO PCD-WINDOWS SOFTWARE. AFTER PROGRAMMING, BE SURE TO RUN THE PCD-WINDOWS ERROR-CHECK UTILITY TO GUARD AGAINST PROGRAMMING CONFLICTS FOR THE TYPE OF SERVICE SELECTED FOR THE INSTALLATION.
  • Page 4: System Programming Options

    SYSTEM PROGRAMMING OPTIONS INTRODUCTION The GEM-P1664EX control panel may be programmed by various means, each of which will be covered in detail in the sections that follow. Keypad displays shown are for a GEM-K2AS, GEM-K3DGTL and GEM-K4RF series keypads. With the GEM-RP2ASe2 and GEM-K2AS keypads, because of their reduced display capabilities, messages are abbreviated and will scroll through two or more screens.
  • Page 5: Easy Menu Driven Program Mode

    Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press the button to enter the Direct Address Program Mode; (b) access Location 2285 (Clear Program); (c) press the button and start over. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 6: Gem-Rp2Ase2/Gem-K2As Keypad Easy Program Menu

    Areas 1-4. The Direct Address Program Mode can then be used to remove zone from Area 1 and place them in Areas 2, 3 or 4. See Zone Options. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 7: Interior (Stay) Bypass Zones In Area 1

    Valid entries are from 01 to 64. Directly enter each zone number, including leading zeros. Zn#XX • Press to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed. (Direct Entry) NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 8: Auto Bypass Re-Entry Zones

    Press the NEXT/YES but- _ _ _ _ _ _ ton to proceed. Central Station Receiver 2 and 3 Telephone Numbers can only be entered in Direct Address NOTE: (Direct Entry) Programming. See CS Receiver Options. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 9: Central Station Receiver 1 Account Number

    Options Level (OPT). Refer to the table on the next page for the available area options. Note: Duplicate ACC __ User Codes are not allowed; therefore a duplicate Code entered in the LCD Window will erase when (Direct Entry) pressed. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 10: Rf Transmitter Points

    Example. A 2-point transmitter has the RF ID number 287613:1. Map point 1 to Zone 6 and point 2 to Zone 9. If a receiver is already installed in the panel, Napco transmitter wireless points can be programmed automatically (“enrolled”) 1.
  • Page 11: Key Fob Transmitters

    The key fob is converted to a “panic only” device. ZONE DESCRIPTIONS: GEM-RP2ASe2 cannot be used to enter Zone Descriptions. To enter Zone Descriptions, you must use the GEM-RP1CAe2 Keypad / GEM-K1CA Keypad (See WI1386) or the Napco PCD-Windows Quickloader Software. Dealer Code D Code Directly enter the Dealer Code (default = 456789), including leading zeros.
  • Page 12: Clear Program

    Data and System Status Data (similar to a new panel). (Direct Entry) Access address 2286, then press the button. Data entry is not allowed. NOTE: Some features (schedules) can only be programmed again with the Downloading Software. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 13: Gem-Rp3Dgtl/Gem-K3Dgtl And Gem-Rp4Rfc/Gem-K4Rf Keypad Easy Program Menu

    Press the NEXT/YES button to proceed. INTERIOR BYPASS FIRE/TBL SYS TBL CHIME NOTE: Exit/Entry Zones will have an entry delay of 30 seconds and an exit delay of 60 seconds. (Direct Entry) NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 14: Interior Zones

    Press the NEXT/YES button to pro- ceed. INTERIOR BYPASS FIRE/TBL SYS TBL CHIME NOTE: A PGM2 Output Timeout of 15 Minutes will automatically be programmed. (Direct Entry) NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 15: Sensor Watch Zones

    INTERIOR BYPASS FIRE/TBL SYS TBL CHIME The SIA CP-01 Features are designed to reduce the incidence of false alarms. NOTE: Do not (Press YES or NO) enable unless reporting, otherwise system trouble Fail to Communicate may occur. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 16: Number Of Keypads

    ANY User Code as the same digits entered for the “Ambush Prefix”. If the programmed code is less than 6 digits, press to set the cursor to USER OPTIONS. Refer to the tables on the next page for the available User Option data entries. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 17: Rf Transmitter Points

    3. Open the loops of points 1, 2 and 3. 4. Install the transmitter battery. The keypad will beep 3 times to If a receiver is already installed in the panel, Napco transmitter indicate that three points have been programmed.
  • Page 18: Key Fob Transmitters

    NOTE: If assigning a key fob to a zone, the “ON/OFF” buttons on the key fob will no longer arm/ disarm the system. The key fob is converted to a “panic only” device. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 19: Dealer Code

    ZONE DESCRIPTIONS: GEM-K3DGTL cannot be used to enter Zone Descriptions. To enter Zone Descriptions, you must use the GEM-K1CA Keypad or the Napco Quickloader Software. DATE ENTRY: GEM-K3DGTL cannot be used to enter the date. To enter Date, you must use the GEM-K1CA Keypad (Version 5 or later) or the Napco Quickloader Software.
  • Page 20: Direct Address Program Mode

    (The panel and keypad version appears briefly on the keypad display). 4. Press C to exit Easy Menu Driven Program Mode & enter Direct Address Program Mode. (For keypad display examples when in Program Mode, see next page). NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 21: Keypad Address Program Mode Display

    C O M P U T E R I Z E D S E C U R I T Y S Y S T E M To exit, press C. NOTE: Press 0 button to clear character at cursor. Select NEXT/PRIOR Address. Press to jump to next programming block. * Press through for 10-15, respectively. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 22: Direct Address Programming Example

    It is using number buttons (0-9). Select NEXT/ PRIOR/NO recommended that the panel be uploaded to Napco's Quickloader software following any keypad programming and that PRIOR address 4. Press to save.
  • Page 23: Conventions Used In This Manual

    DATA ENTRY SELECTIONS ENTRY PRESS KEYPAD minor field alterations to an existing panel program. It is TOTAL DISPLAYS (BINARY VALUE CIRCLED) recommended that the panel be uploaded to NAPCO's ENTER DATA PROGRAM THE DATA ENTRIES PCD-Windows software following keypad blank •...
  • Page 24: System Delays & Timeouts

    4. For more information on a programming B. Divide it by 16 option refer to the Glossary at the end of 1 Quotient Left Digit this manual. 4. Press to save. 16 20 4 Remainder Right Digit NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 25: System Output Timeouts

    1. Enter in 1st and 2nd Leading Digits in right digit only (left digit is not used) as shown. Pager Format LEFT RIGHT (2nd Digit) blank (•) 2. Valid entries are: 0-9. [Default = blank (•) blank (•)] 3. Press to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 26: System Options

    2045 is not left blank (•), then the 2-digit Global Ambush Code is the two digits entered in address Ambush Code 2045. [Default = blank (•) blank (•)] Enter in address location (both left and right digits) ; valid entries are 1-9. Press to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 27: System Options

    2. Add the data values (ex: F=15=(1+2+4+8) from the selected options. See page 23). 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. 4. Press to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 28: System Options

    2-digit “Global Ambush Code” in Address 2045. If Address 2045 is left blank (•), then, the 2-digit “Global Ambush Code” 4. Press to save. will be “99”. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 29 2. Add the data values (ex: F=15=(1+2+4+8) from the selected options. See page 23). 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. 4. Press to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 30: Cs Receiver Options

    2. Enter up to 20 digits from left to right. NOTE: Leave trailing boxes blank (•). For a zero, press G0. 3. Valid entries are: 1-9, B = button, C = button, D = 3 sec. pause, E = Wait for dial tone, F = ignore location. Press to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 31: Cs Subscriber Id Options

    Enter 3 or 4 digits (depending on the CS receiver format) for each subscriber number from left to right. NOTE: Leave trailing boxes blank (•). For a zero, press G0. Valid entries are: 1-9, 0 and B-F. NOTE: A is not permitted. Press [Enter] or [ON/OFF] to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 32: Cs System Reporting Options

    2. Add the data values (ex: F=15=(1+2+4+8) from the selected options. See page 23). automatically to Rotary Dialing. Leave blank (•) to select Rotary Dialing. 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. Press to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 33: Zone Anding Time Window

    2. Add the data values (ex: F=15=(1+2+4+8) from the selected options. See page 23). 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. Press to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 34: Cs Zone Reporting Options

    MODEM CODES determine the zone types reported for the following formats: SIA and ADEMCO Point ID. Gas Alarm 1. Select the desired Modem Code for each zone from the table shown. Heat Alarm Auxiliary Alarm 2. Press to save. 24 Hour Auxiliary NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 35: Cs User Reporting Options

    2. Add the data values (ex: F=15=(1+2+4+8) from the selected options. See page 23). 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. 4. Press to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 36 2. Add the data values (ex: F=15=(1+2+4+8) from the selected options. See page 23). 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. 4. Press to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 37: Ezm Group Options

    2. Enter either blank (•) or "1" in corresponding address locations 29-32 37-40 4-Zone EZM 33-36 41-44 above. 37-40 45-48 41-44 49-52 NOTE: Dark shaded data value box shows option not available. 45-48 53-56 3. Press to save. 49-52 57-60 53-56 61-64 57-60 61-64 NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 38: Area Bell Control Options

    (1,2,3,4) accordingly. For example, if you wish to grant an Area 1 keypad the ability to turn off an Area 2 PGM2 output, enter "2" in Address 1485. Enter digit in address location. NOTE: Dark shaded data value box shows option not available. Press to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 39 (1,2,3,4) accordingly. For example, if you wish to grant an Area 1 keypad the ability to turn off an Area 2 PGM2 output, enter "2" in Address 1485. Enter digit in address location. NOTE: Dark shaded data value box shows option not available. Press to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 40 (1,2,3,4) accordingly. For example, if you wish to grant an Area 1 keypad the ability to turn off an Area 2 PGM2 output, enter "2" in Address 1485. Enter digit in address location. NOTE: Dark shaded data value box shows option not available. Press to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 41 (1,2,3,4) accordingly. For example, if you wish to grant an Area 1 keypad the ability to turn off an Area 2 PGM2 output, enter "2" in Address 1485. Enter digit in address location. NOTE: Dark shaded data value box shows option not available. Press to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 42: Keypad Options

    KEYPAD OPTIONS: Select options for any of the 7 keypads. Select the desired option entering the option number (1-8) for each digit. Enter corresponding option number in address location. NOTE: Dark shaded data value box shows option not available. Press to save. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 43: Temperature Display At Keypad

    Note: If these three addresses are set and power (AC and battery) are subsequently removed, they keypad will indicate that the time and date are lost and will need to be reset. See WI1425 for more information. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 44: Area Arming Options

    (5) 1/100 sec. = 50ms. blank (•) (6) 1/100 sec. = 60ms. blank (•) 4 Remainder Right Digit (7) 1/100 sec. = 70ms. blank (•) (8) 1/100 sec. = 80ms. blank (•) (255) 1/100 sec. = 2.55 sec. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 45: Zone Options - Zones 1 To 16

    0490 Priority with Bypass 4 2 1 4 2 1 Auto-Bypass NOTE: Dark shaded boxes = option not available. 4 2 1 See Direct Address Programming Example page 22. Selective Bypass 4 2 1 NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 46: Zone Options - Zones 17 To 32

    --Pulse Alarm Output is enabled for the zone number(s) entered in “FIRE ZONES ENTER ZONE #” or “2-WIRE FIRE ZNS ENTER ZONE #”. --Fire is enabled for the zone number(s) entered in “FIRE ZONES ENTER ZONE #”. --2-Wire Smoke Detector is enabled for the zone number(s) entered in “2-WIRE FIRE ZNS ENTER ZONE #”. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 47: Zone Options - Zones 33 To 48

    0490 Priority with Bypass 4 2 1 4 2 1 Auto-Bypass NOTE: Dark shaded boxes = option not available. 4 2 1 See Direct Address Programming Example page 22. Selective Bypass 4 2 1 NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 48: Zone Options - Zones 49 To 64

    --Pulse Alarm Output is enabled for the zone number(s) entered in “FIRE ZONES ENTER ZONE #” or “2-WIRE FIRE ZNS ENTER ZONE #”. --Fire is enabled for the zone number(s) entered in “FIRE ZONES ENTER ZONE #”. --2-Wire Smoke Detector is enabled for the zone number(s) entered in “2-WIRE FIRE ZNS ENTER ZONE #”. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 49: External Relay Control

    Timeout Event ID COND. RELAY # AREA Timeout Event ID COND. RELAY # AREA Timeout Event ID COND. (•) (•) (•) (•) (•) (•) CONTINUED ON NEXT PAGE [Default = blank (•) blank (•) from address 1489-1608] NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 50 Timeout Event ID COND. (•) (•) To program, follow the 5 steps below: STEP 1: RELAY # OPTIONS: The GEM-P1664EX supports 8 external relays from Relay Module RM3008. Multiple events may be "mapped" to each relay, Step Step Step Step Step up to a maximum of 16 events.
  • Page 51 Relay Control Group 2 Area 2 Fail to Open Zone 36 Entry Relay Area 1 Area 2 Fail to Close Zone 37 Entry Relay Area 2 Entry Relay Area 3 Entry Relay Area 4 NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 52: Rf Receiver & Supervisory Timer Options

    (•) 360 min. blank (•) 390 min. NOTE: These timers apply only to Supervised RF Transmitters (see RF Transmitters in Easy blank (•) 420 min. Menu Driven Mode Programming). blank (•) 450 min. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 53: Clear Program Options

    2. Press Q Until “TURNON PROG Y/N” (GEM-RP2ASe2/GEM-K2AS) or “17” (GEM-RP3DGTL/GEM-K3DGTL or GEM-RP4RFC/GEM-K4RF) appears on the LCD screen. 3. Press P To Enter User Program Mode. 4. Press C To Exit User Program Mode when finished. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 54: User Codes

    User Number each code. FIRE TROUBLE G 0 button to clear character at cursor. NOTE: Press BYPASS CHIME To continue press P or Q button. User Code (Direct Entry) Programming User Codes with GEM-K4RF Keypad NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 55: Keypad Configuration Mode

    TOUCHPAD BACK LIGHT Cut Jumper A to disable touch pad backlighting to conserve 11mA standby current. LCD BACKLIGHT Cut Jumper B to disable LCD backlighting. DISABLE SOUNDER Cut Jumper C to disable the sounder. NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 56: Alphabetical Index

    CONTROL PANEL ZONES REPORT CODE, 34 AUTO BELL TEST ON ARMING ADDRESS 1421, 28 CONVENTIONS USED IN THIS MANUAL, 23 AUTO BYPASS RE-ENTRY ZONES: EASY PROGRAM MENU, CS AREA & SYSTEM REPORTING OPTIONS (ADDRESS 0785, NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 57 ENTRY/EXIT 1--ZONE OPTION, 45, 46, 47, 48 DISABLE ZONE FAULT SCROLLING ADDRESS 1420, 28 ENTRY/EXIT 2--ZONE OPTION, 45, 46, 47, 48 DON'T CLEAR PGM2 OUTPUT WITH DISARM ADDRESS ERASE DEALER PROGRAM, 12, 18 1424, 28 ERASE ENTIRE PROGRAM, 12, 18 NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 58 OPENING AFTER ALARM REPORTING OPTIONS ADDRESS KEY FOB TRANSMITTERS AS ZONE INPUT DEVICES, 18, 19; 0679, 32 EASY PROGRAM MENU, 11 OPENING REPORT ONLY AFTER ALARM REPORT ADDRESS KEY FOB ZONE ASSIGNMENT, 18; EASY PROGRAM MENU, 1420, 28 NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 59 SYSTEM PROGRAMMING OPTIONS, 4 RADIONICS FAST RECEIVER FORMAT, 16 SYSTEM RESPONSE ACTIVATED BY AREA 1 EVENT/ RADIONICS FORMAT, 30 TROUBLE, 26 RADIONICS MODEM 2 RECEIVER FORMAT, 16 SYSTEM RESPONSE ACTIVATED BY AREA 2 EVENT/ NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 60 VERI-PHONE ZONES TRIP PGM2 OUTPUT ADDRESS 1424, VERTEX RECEIVER FORMAT, 16 WIRELESS TROUBLE ACTIVATES TELCO 1 ADDRESS 1423, WIRELESS TROUBLE ACTIVATES TELCO 3 ADDRESS 1423, WIRING DIAGRAM, 64 XMITTER LOW BATTERY REPORTING OPTIONS ADDRESS NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 61: Address Number Location Index

    ADDRESS 0788 TOUCH-TONE DIALING ONLY ADDRESS 0788 TOUCH-TONE DIALING W/ROTARY BACKUP ADDRESS 0836 ALARM OUTPUT ADDRESS 0837 PULSED ALARM OUTPUT ADDRESS 0838 PGM1 OUTPUT ADDRESS 0839 PGM2 OUTPUT ADDRESS 0840 REPORT EVENT TELCO 1 NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 62 DISABLE 2ND CALL ANS. MACHINE OVERRIDE ADDRESS 1424 DISABLE CODE REQUIRED FOR EZ BYPASS ADDRESS 1424 DON'T CLEAR PGM2 OUTPUT WITH DISARM ADDRESS 1424 ENABLE LOOP SUPERVISION ADDRESS 1424 RESOUND ON WIRELESS SMOKE LOW BATTERY NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 63 ZONE RESPONSE TIME ADDRESS 2281 CLOCK ADJUSTMENTS ADDRESS 2281 CLOCK SOURCE (INTERNAL PANEL) ADDRESS 2281 ENABLE DAYLIGHT SAVING TIME ADDRESS 2281 LINE FREQUENCY--ENABLE 50HZ ADDRESS 2285 CLEAR PROGRAM ADDRESS 2286 COLD START 12, 18 NAPCO Security Systems GEM-P1664EX Programming Instructions...
  • Page 64: Gem-P1664Ex Wiring Diagram

    Page 64 WI1387 7/05 GEM-P1664EX WIRING DIAGRAM NAPCO Security Systems GEM-P1664EX Programming Instructions...