Keypad Configuration Mode; Keypad Installation; Configuring The Keypads - NAPCO LIBRA-P432EX Series Programming Instructions Manual

Control panel/communicator
Table of Contents

Advertisement

Page 42

KEYPAD CONFIGURATION MODE

This section will focus on configuring the GEM-DXRP1 or GEM-DXK1 Keypads. If there is more than one keypad in the system, we
recommend that either a GEM-DXRP1 or a GEM-DXK1 keypad be used for programming.

KEYPAD INSTALLATION

Several types of keypads may be used with the LIB-P432EX: The GEM-DXRP1 / GEM-DXK1 , the GEM-DXRP2 / GEM-DXK2, the
GEM-DXRP3 / GEM-DXK3, and the GEM-DXK4RF series (see WI1771). Each must be assigned an address number (1–7) and each
requires its own configuration procedure (see CONFIGURING THE KEYPADS, which follows, and DIRECT ADDRESS KEYPAD
AREA OPTIONS). At least 1 keypad must be used; only 1 is required for a single-area Commercial Burglary installation.
GEM-DXRP1/GEM-DXK1 - is a 2-line combination fire/burglary/access keypad capable of supporting a PGM output. The
GEM-DXRP1 or GEM-DXK1 is recommended for programming. See "Important Note" on page 2 for more information
regarding the buttons on the GEM-DXRP1/GEM-DXK1 keypads.

CONFIGURING THE KEYPADS

A total of up to seven (7) keypads may be connected to the panel. GEM-DXRP1 / GEM-DXK1 , the GEM-DXRP2 / GEM-DXK2, the
GEM-DXRP3 / GEM-DXK3, and the GEM-DXK4RF series keypads require different configuration procedures, as described below
and in WI1771.
Configuring the GEM-DXRP1/GEM-DXK1 Keypad
Each GEM-DXRP1/GEM-DXK1 keypad must be configured for (a) keypad tactile beep; (b) entry sounder; (c) keypad address and (d)
compatibility number.
To enter the Keypad Configuration Mode:
1. Move jumper JP1 (located in the center of the control panel board) from Pins 1-2 (top two) to Pins 2-3 (bottom
two). NOTE: See Wiring Diagram at the end of this manual.
2. After about 15 seconds, the display will read "XX OUT OF SYSTEM", where XX indicates the keypad address.
3. Press
11123w
all keypads).
Keypad Beep
Entry Sounder
Keypad Address
LIBRA LIB-P432EX Series Programming Instructions
and proceed as follows. (Repeat the following procedure for
Keypad Tactile Beep
Upon entering the Keypad Configuration Mode, "KEYPAD BEEP ON" will be displayed,
indicating that the tactile beep, which sounds when any button is pressed, is on.
ON
To turn off the tactile beep, press the
tile beep on and off). Press
Entry Sounder
To turn off the keypad entry sounder during entry time, press
ON
will toggle the entry sounder on and off). Press
y
to exit.
Keypad Address
01
If more than one keypad is installed, each must be assigned a unique keypad
address (that is, no two keypads may be numbered alike):
Keypads must be numbered consecutively (missing numbers are not permitted)
To assign the keypad number, proceed as follows:
1. Enter the assigned keypad number 01–07, then press
number will be acknowledged by a short beep; an invalid number will be re-
jected by a long beep.
2. Press
w
to continue or press
u
u
button (the
w
to continue or press
w
to continue or press
y
to exit.
NAPCO Security Systems
NORMAL
KEYPAD
CONFIGURE
button will toggle the tac-
y
to exit.
u
u
(the
button
u
to save. A valid

Advertisement

Table of Contents
loading

Table of Contents