User 8 code as an Ambush code. • Ordering Information ..........4 Wireless Ready Optional Accessories ..........4 • The GEM-P800 is wireless ready. When used with a Bell Supervision Programming the Panel .........5 GEM-RECV-XP8 receiver, the control panel can sup- • Line Cut Detection Installation .............6...
3. Connect terminal 15 (PGM) to terminal 3. method of establishing a connection. The 4. Apply power to the GEM-P800 control panel. power up method is recommended if the panel is at- 5. After a few seconds the ARMED, READY tempting to report.
WI850D GEM-P800 Installation Instructions Installation Wiring For increased protection, additional detectors should be installed in areas other than those Terminal Block Wire Range: 14-22 AWG. required, such as the dining room, bedrooms Mounting the Panel and utility room. Heat detectors, rather than...
Burglary Zone Wiring Fire Zone Wiring Keypad Sounder Wire the Fire Zone as shown in the Wiring Dia- NAPCO's EZ Zone Doubling is simple. Each gram in the back of this manual. An EOL resis- QUICK BEEPS terminal has 2 zones, use an E (2.2 K) type...
WI850D GEM-P800 Installation Instructions Panel Operation Keypad LED's Keyfob have been programmed for Full Set [81- 84]. To arm the system with all zones protected ARMED LED DEFINITION Arming (System ON) press the key. Press and hold the Armed ............ON Before arming the system close all protected key for 1.5s to fully set the system (the LED...
Home Bypassing a zone press . If a valid Arm/Disarm code is entered, Press the key, then the zone number to be Exit/Entry Zone is not violated the keypad will beep 6 times, indicating the Zones selected as Home/Away with Delay bypassed.
WI850D GEM-P800 Installation Instructions While in User Program Mode, Zones 1 through 8 battery is tested during a Bell Test, and auto- value of 1234, program the 4-digit User 1 Code through Dealer Programming [95]. User 1 Arm/ will light to indicate any User Codes presently...
SIGNAL STRENGTH KEYPAD SOUNDER been selected as an Exit/Entry Follower Zone, ready, tell the installer to arm, then disarm. Home/Away with Delay Zones, or 24 Hour Zone. Then enter in order to establish a 3 or less .25s BEEP connection. Phone connection to installer will BEEP + User 1 Code - User Program go "dead"...
WI850D GEM-P800 Installation Instructions Remote Activation Zone Features Using NAPCO's Quickloader Software is Entered during Exit Time, Home/Away with [00] Exit/Entry Zones Delay Zones will be automatically bypassed, even if the (Version 3.26 or higher), follow the instruc- Exit/Entry Zone is violated. Easy Exit/Easy Arm [22-2] must...
cally be unbypassed and any subsequent allows the user time to enter and disarm the [07] Burg (Steady) Output violations of the zone will cause an alarm system. Upon entering, the keypad sounder Enables the Bell Output on a zone trip for condition.
WI850D GEM-P800 Installation Instructions does not receive any signal (either a trip or a Enter turn the Bell on unless this option is pro- status) from a transmitter in the time speci- New Test Timer Offset: 12 hours grammed. fied, a system trouble 'RF Supervisory Fail-...
(4) Bell on Line Cut (Armed) - Program to (3) Inhibit Fail-to-Communicate Dis- turn the Bell Output on if the telephone line play - This option prevents the keypad from [24] Programmable Output Features 2 has been cut while the panel is armed. either indicating or sounding when a Fail to (1) Fire - Program to activate the PGM on Communicate has occurred.
WI850D GEM-P800 Installation Instructions to disable reporting to Telco 1. Select zone(s) required to send a restore AC Restore report. report to Telephone Number 1. The zones (2) Battery Restore - Program to activate [0] Disabled [4] Universal High Speed will send a restore after Bell time-out, unless a Battery Restore report.
[42] Receiver Format (Telco 2) (2) 2:1 Rotary Dialing - Changes the Digits in Report Codes and subscriber IDs that are pro- make break ratio when rotary dialing from Select the format that will be used to report grammed with "B" through "F" will be converted to "0"s. 1.5:1 to 2:1.
WI850D GEM-P800 Installation Instructions sent, but the event code and subscriber ID [61] Point ID Report Codes Fire, Keypad AUX, Keypad Panic, Test are not transmitted. With this option se- Timer, AC Fail, Low Battery, Trouble and Point ID Report Codes are defaulted to Bur- lected, a telephone number programmed in Fire.
) [20-3] Up to two receivers can be wired to the Programming Example GEM-P800. Each wireless transmitter can Panic Report to Telco 1[36-2] and/or Telco 3 Map point 1 of a window door transmitter be mapped to a zone. Only 1 wireless de-...
WI850D GEM-P800 Installation Instructions Audible Panic (Optional) [21-1] option to activate the PGM Output for 5 sec- less Smoke Supervisory Timer, a system onds when the buttons on the trouble 'RF Smoke Supervisory Failure' will 2 AUX be indicated on the keypad.
Wireless Smoke Supervisory Time is downloaded. fixed at 4 hours. PCPreset [94] Dealer Code (4) Fire Trouble on Fire LED - Normally 1. Create the GEM-P800 account to be 4567 The default Dealer Code is . Program all troubles are displayed on the SYS- downloaded using PCD3000 Quick- a new 4-digit Dealer Code.
Page 22
WI850D GEM-P800 Installation Instructions TEM TROUBLE LED, including Fire Trou- ble. If required Fire Trouble can be dis- played on the Fire LED. Fire Trouble is indi- cated by a steady I Fire LED. [97] Dealer Options 2 (1) International Dialing Protocol - No dialing if no dial tone, 60 s between attempts and 4 s wait for dial tone.
System Troubles no more system troubles to view, the system will ZONE LED . For example, a wireless low battery return to normal operation. on zone 2 would beep the keypad sounder 3 times and turn on zone 2 LED. Use the System Trouble chart on the following Audible System Trouble Indication - For all EXAMPLE...
Page 24
WI850D GEM-P800 Installation Instructions System Troubles Keypad Beeps or Zone LED System Trouble SYSTEM Cause/Action Condition Flashes 1 Beep AC Power Failure This trouble will occur if AC power is not present. Ensure that the transformer is connected to an unswitched power source.
with Delay Zones programmed as When the PGM lug of the control Troubleshooting Exit/Entry Followers. panel is programmed for an Armed indication, it also incorporates an Zones programmed for 24 Hour Alarm Memory function which will The bell output drops to about 3 Protection.
Page 26
WI850D GEM-P800 Installation Instructions The Keypad is not receiving a POLL alarm. Enter to turn from the Panel. keypad sounds back on. Transmitters not responding? Check Keypad wiring. • Open Transmitter case; keypad should into X-Mitter Tamper • The Panel is in the process of being Trouble.
NAPCO neither assumes, nor authorizes any other person purporting to act on its behalf to modify, to change, or to assume for it, any other warranty or liability concerning its products. In no event shall NAPCO be liable for an amount in excess of NAPCO's original selling price of the product, for any loss or damage, whether direct, indirect, incidental, consequential, or otherwise arising out of any failure of the product.