Keypad Options (Address 2425-2446) - NAPCO GEMINI GEM-P3200 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEMINI GEM-P3200:
Table of Contents

Advertisement

WI818G 10/05
ADDRESS 2425
Keypad 1 Type
LEFT
RIGHT
& Area
Assignment
[Default = blank (•) 1]
ADDRESS 2429
Keypad 5 Type
LEFT
RIGHT
& Area
blank (•)
Assignment
[Default = blank (•) blank (•)]
KEYPAD TYPE & AREA ASSIGNMENT: Up to 7 keypads may be programmed, if they
are connected.
NOTE: See Keypad Configuration Mode. By default from the factory, each keypad is
configured as number 1.
1. Select keypad type & area assignment for each keypad from the tables shown.
2. Enter in corresponding right and left digit address locations above.
KEYPAD NUMBER
1
2
3
4
5
6
7
KEYPAD OPTIONS: Select options for any of the 7 keypads.
* Note: For Remote Access Control only (no Arm/Disarm capability).
1.
Select the desired option entering the option number (1-8) for each digit.
2.
Enter corresponding option number in address location.
U
D
3.
Press
or
to save.
NOTE: Dark shaded data value box shows option not available.
L
NAPCO Security Systems
KEYPA D OPTION S (ADDRES S 2425-2446)
ADDRESS 2426
Keypad 2 Type
LEFT
RIGHT
& Area
blank (•)
Assignment
[Default = blank (•) blank (•)]
ADDRESS 2430
Keypad 6 Type
LEFT
RIGHT
& Area
blank (•)
Assignment
[Default = blank (•) blank (•)]
KEYPAD
KEYPAD
ADDR
FIRE
AUXILIARY
1
2440
default ON default ON default ON
2441
default ON default ON default ON
2442
default ON default ON default ON
2443
default ON default ON default ON
default ON default ON default ON
2444
2445
default ON default ON default ON
default ON default ON default ON
2446
[Defaults as noted for address 2440-2446]
ADDRESS 2427
Keypad 3 Type
LEFT
& Area
blank (•)
Assignment
[Default = blank (•) blank (•)]
ADDRESS 2431
Keypad 7 Type
LEFT
& Area
blank (•)
Assignment
[Default = blank (•) blank (•)]
LEFT
blank
KEYPAD OPTIONS
Rem. Acc.
KEYPAD
AMBUSH
Only *
PANIC
2
3
4
default ON
default ON
default ON
default ON
default ON
default ON
default ON
X
GEM-P3200 Programming Instructions
Page 37
ADDRESS 2428
Keypad 4 Type
LEFT
RIGHT
& Area
blank (•)
Assignment
[Default = blank (•) blank (•)]
RIGHT
KEYPAD TYPE
KEYPAD AREA
ASSIGNMENT
OPTION
RIGHT
Burg Keypad
(•)
blank (•)
2
Wizard Keypad
1
2
EASY
PANEL
ARMING
ACCESS
STATION
5
6
7
RIGHT
OPTION
Not Used
Area 1
Area 2
TOUR
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gem-p3200

Table of Contents