Page 2
NOTE: For specific information on any of the listed programming options refer to the Glossary in the GEM-P3200 Installation Instructions (WI817). NAPCO Security Systems, Inc. 333 Bayview Avenue, Amityville, New York 11701 For Sales and Repairs, call toll free: (800) 645-9445 For direct line to Technical Service, call toll free: (800) 645-9440 Internet: http://www.napcosecurity.com...
EXPERIENCE AND INSTALLATION EQUIPMENT. THE UNIT IS DESIGNED TO BE PROGRAMMED USING AN IBM-COMPATIBLE COMPUTER WITH NAPCO PCD3000 SOFTWARE. AFTER PROGRAMMING, BE SURE TO RUN THE PCD3000 ERROR-CHECK UTILITY TO GUARD AGAINST PROGRAMMING CONFLICTS FOR THE TYPE OF SERVICE SELECTED FOR THE INSTALLATION.
For a direct high-speed data transfer to the control panel from a desktop computer, connect the download jack (J1) on the panel to the LOCAL jack (J3) on the Napco PCI2000/3000 computer interface using the supplied 6-conductor cable. (Refer to PCI2000/3000 Installation Instructions WI443 for wiring diagram and procedures.) Similarly, a high-speed local download may be made in the field using a notebook or laptop computer.
Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press the button to enter the Direct Address Program Mode; (b) access Location 4091 (Clear Program); (c) press the button and start over. NAPCO Security Systems GEM-P3200 Programming Instructions...
Sescoa, Vertex, DCI, Franklin Fast Radionics Modem 2 Direct Address Programming. See CS Re- Radionics Fast ceiver Options. Silent Knight Fast Ademco Point ID Radionics, DCI, Franklin Slow Ademco Express Universal High Speed Pager Radionics BFSK NAPCO Security Systems GEM-P3200 Programming Instructions...
SERVICE LEVEL 3 SERVICE Note: “Y” indicates option is enabled. Note: “Y” indicates option is enabled. Note: Users are assigned to areas in “Enable User Code by Area” (Address 2500-2531) in Direct Address Programming. NAPCO Security Systems GEM-P3200 Programming Instructions...
Zone Number using the buttons. Program a new description as above. NOTE: Zone Descriptions can only be entered through the GEM-RP1CA/RP1CAe/RP1CAe2 Keypad or by using the Napco Quickloader Software. Press NEXT ( ) button to proceed. NAPCO Security Systems...
Press NEXT ( ) button to proceed. Quick Method. If a receiver is already installed in the panel, Napco transmit- ter wireless points can be programmed automatically (“enrolled”) using the following procedure. NOTE: The transmitter point will be enrolled only if the signal strength is 3 or greater.
CLEAR PROGRAM: Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press the button to enter the Address Program Mode; (b) access Location 4091 (Clear Program); (c) press start over. NAPCO Security Systems GEM-P3200 Programming Instructions...
10 digits in this mode. To program additional digits, go to the Direct Address Program Mode and continue from Location 0537. Central Station (Direct Entry) Receiver 2 and 3 Telephone Numbers can only be entered in Direct Address Programming. See CS Receiver Options. NAPCO Security Systems GEM-P3200 Programming Instructions...
Keypad 1–4 data in the right digit; and the data for Keypad 5–7 data in the left digit. (Press the buttons for blank.) Note: Users are assigned to areas in “Enable User Code by Area” (Address 2500-2531) in Direct Address Programming. NAPCO Security Systems GEM-P3200 Programming Instructions...
Page 13
CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described above and press to save. Similarly, to cancel a code, blank out each number of the code press to save. NAPCO Security Systems GEM-P3200 Programming Instructions...
(Direct Entry) Quick Method. If a receiver is already installed in the panel, Napco transmit- ter wireless points can be programmed automatically (“enrolled”) using the following procedure. NOTE: The transmitter point will be enrolled only if the signal strength is 3 or greater.
EXIT DEALER PROGRAM MODE: This completes the custom default program. Press the button to enter the Direct Address Program Mode for further programming or press the button once again to end all programming and (Direct Entry) resume normal keypad operation. NAPCO Security Systems GEM-P3200 Programming Instructions...
To Enter Dealer Program Mode 4. Press To Exit Easy Menu Driven Program Mode & Enter Direct Address Program Mode GEM-RP1CA/RP1CAe/RP1CAe2 Keypad GEM-RP2AS/RP2ASe/RP2ASe2 Keypad = ADDRESS LOCATION = DATA ENTRY LOCATION (Left and Right Digits) NAPCO Security Systems GEM-P3200 Programming Instructions...
It is blank • recommended that the panel be uploaded to Napco's Quickloader software following any keypad programming and that the PCD3000's error-check feature be utilized to reduce the possibility of programming omissions or con- flicts.
5. Press to enter an “E” in the left digit and press to enter a blank (•) in the right digit. 6. Press to save. Address 1218 is now programmed with “E•”. NAPCO Security Systems GEM-P3200 Programming Instructions...
Determining data entry for a location (each “nibble”). Numbers in parentheses indicate data for selected zones or features. (See Programming Worksheets that follow.) DEFAULTS: The defaults shown on the following pages are automatically set after exiting the Easy Menu Driven Mode. NAPCO Security Systems GEM-P3200 Programming Instructions...
A. Choose a desired delay/timeout , ex: 20. Note: For Sensor Watch only divide it by 10, ex: 20/10 = 2 1 Quotient Left Digit B. Divide it by 16 16 20 4 Remainder Right Digit NAPCO Security Systems GEM-P3200 Programming Instructions...
DEALER SECURITY CODE: Enter up to 6 digits to be used by the dealer to enter programming. 1. Enter in both left and right digits of address locations. 2. Valid entries are: 0-9. Note: If left blank, the Master Security Code must then be used to enter programming. NAPCO Security Systems GEM-P3200 Programming Instructions...
No blank spaces in between; leave blank (•) any trailing boxes. If an “Ambush Code” (Address 0495) is entered, do not program the first two digits of ANY User Code as the same digits entered for the “Ambush Code”. NAPCO Security Systems GEM-P3200 Programming Instructions...
Page 24
Keypad 5–8 data in the left digit. Note: Press the buttons for blank. DISPLY RF XMITTER STAT RELAY CONTROL Note: Users are assigned to areas in “Enable User Code by Area” (Address 2500-2531). NAPCO Security Systems GEM-P3200 Programming Instructions...
(left and right). 2. Add the data values (ex: 15=1+2+4+8) from the selected options. 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
1. Enter in right digit only (left digit is not used). 2. Valid entries are: 0-9. 2. Valid entries are: 1 or 2. Note: Download Security Code must match the code entered in the PCD3000 Software. NAPCO Security Systems GEM-P3200 Programming Instructions...
3. To disable a code leave boxes [Default = blank (•) blank (•) from address 0860-0869] Fail to Close 0868 blank (•). Fail to Open 0869 NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
(•) to select Rotary Dialing. 2. Add the data values (ex: 15=1+2+4+8) from the selected options. 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
MODEM CODES determine the zone types reported for the following formats: SIA and ADEMCO Point Hold up Gas Alarm 1. Select the desired Modem Code for each zone from the table shown. Heat Alarm Auxiliary Alarm 24 Hour Auxiliary NAPCO Security Systems GEM-P3200 Programming Instructions...
(left and right). 2. Add the data values (ex: 15=1+2+4+8) from the selected options. 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
Page 31
(left and right). 2. Add the data values (ex: 15=1+2+4+8) from the selected options. 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
(left and right). 2. Add the data values (ex: 15=1+2+4+8) from the selected options. 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
Pulse Alarm Output is enabled for the zone number 8 entered in “ ”
Fire is enabled for zone number 8 entered in “ ”
2-Wire Smoke Detector is enabled for zone number 8 entered in “ ” NAPCO Security Systems GEM-P3200 Programming Instructions...
(left and right). 2. Add the data values (ex: 15=1+2+4+8) from the selected options. 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
(left and right). 2. Add the data values (ex: 15=1+2+4+8) from the selected options. 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
PRIORITY ARMING/AREA 1 PRIORITY ARMING/AREA 2 DATA ENTRIES DATA ENTRIES OPTION OPTION LEFT RIGHT LEFT RIGHT blank (•) blank (•) Not Used blank (•) blank (•) Not Used blank (•) blank (•) Enabled Enabled NAPCO Security Systems GEM-P3200 Programming Instructions...
1. Select the number of relay modules from the table shown. blank (•) None [Default = blank (•) blank (•)] 2. Enter in corresponding right digit address location shown (left digit is not used). NAPCO Security Systems GEM-P3200 Programming Instructions...
2. Select the area from the table blank (•) blank (•) NONE shown; enter in corresponding right blank (•) Area 1 digit address location (left digit is not blank (•) Area 2 used). Area 1 & Area 2 NAPCO Security Systems GEM-P3200 Programming Instructions...
Page 41
ENTRIES Zone 31 Relay Group 2 Alarm Zone 32 Area 1 Entry Delay Restore Area 2 Entry Delay Area 1 Keypad Ambush Trouble Area 1 Keypad Panic Trouble Restore Area1 Keypad Fire Follow Zone NAPCO Security Systems GEM-P3200 Programming Instructions...
GEM-RP1CAe2 Keypad Access address 4093, then press the button. Data entry is not allowed. NOTE: Some features (schedules) can only be programmed again with the GEM-RP2ASe2 Keypad Downloading Software. NAPCO Security Systems GEM-P3200 Programming Instructions...
Enter a User Number (01–32) using the button to clear character at cursor. NOTE: Press number buttons. The cursor will then To continue press button. advance to the User Code and read the existing code, if any. Programming User Codes NAPCO Security Systems GEM-P3200 Programming Instructions...
Press the button to save. Advance to the next zone as in Steps 1 and 2 above and repeat this procedure until all zones have been programmed. NAPCO Security Systems GEM-P3200 Programming Instructions...
A valid number will be acknowledged by a short beep; an invalid number will be rejected by a long beep. 2. Press the button to continue or press the button to exit. NAPCO Security Systems GEM-P3200 Programming Instructions...
Page 47
3. Enter “14” at the keypad, then press the button. Press the button to continue or press the button to exit the Keypad Configuration Mode (display will read “ ”). Then replace Jumper JP5 across Pins 1–2 (top two). NAPCO Security Systems GEM-P3200 Programming Instructions...
Page 48
Cut Jumper B to disable LCD backlighting. ENTRY SOUNDER Cut Jumper C to disable the sounder. (Do not disable in UL applications.) NAPCO Security Systems, Inc. 333 Bayview Avenue, Amityville, New York 11701 For Sales and Repairs, call toll free: (800) 645-9445 For direct line to Technical Service, call toll free: (800) 645-9440 Internet: http://www.napcosecurity.com...
OPTIONS OPTIONS NOTE: Easy Menu Programming allows programming of users 1-8 for area 1 and users 9-16 for area 2 only. All users (1-32) are programmed in Direct Address Mode. See User Code Options NAPCO Security Systems GEM-P3200 Programming Instructions...
Page 50
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z NAPCO Security Systems GEM-P3200 Programming Instructions...
Page 51
RF Transmitter Points: XMTR ZONE RF ID CHECK POINT XMTR ZONE RF ID CHECK POINT (printed on xmtr box) (printed on xmtr box) Key Fob Transmitters: KEY FOB # RF ID CHECK (printed on xmtr box) NAPCO Security Systems GEM-P3200 Programming Instructions...
Requires dealer code Not avialable in GEM-RP2AS/RP2ASe/RP2ASe2 keypads
Initial Configuration only; suppressed thereafter
NAPCO Security Systems GEM-P3200 Programming Instructions...
Page 53
Minimum level required to access function Level 3 code with appropriate option Requires dealer code Not avialable in GEM-RP2AS/RP2ASe/RP2ASe2 keypads Initial Configuration only; suppressed thereafter NAPCO Security Systems GEM-P3200 Programming Instructions...
Page 54
&*( (at any time) DIRECT ADDRESS PROGRAM MODE Minimum level required to access function Level 3 code with appropriate option Requires dealer code Not avialable in GEM-RP2AS/RP2ASe/RP2ASe2 keypads Initial Configuration only; suppressed thereafter NAPCO Security Systems GEM-P3200 Programming Instructions...
Page 55
Press button (at any time) Minimum level required to access function Level 3 code with appropriate option Requires dealer code Not avialable in GEM-RP2AS/RP2ASe/RP2ASe2 keypads Initial Configuration only; suppressed thereafter NAPCO Security Systems GEM-P3200 Programming Instructions...
Page 56
(“
”) * JP5 is located at the top-right corner of the circuit board. ** If a Compatability Number other than “0000” is programmed, “
” is displayed. NAPCO Security Systems GEM-P3200 Programming Instructions...
CS Receiver 1 Options Direct Address 0526 CS Receiver 1 Telephone Number Direct Address 0527-0546 CS Receiver 2 Format Direct Address 0550 CS Receiver 2 Options Direct Address 0551 CS Receiver 2 Telephone Number Direct Address 0552-0571 NAPCO Security Systems GEM-P3200 Programming Instructions...
Page 59
RF Transmitter Points Easy Menu Driven RF Trouble Report Code Direct Address 0897 Selective Bypass (Zone Option) Direct Address 1205, 1305, 1405 & 1505 31 & 32 Sensor Watch Report Code Direct Address 0877 NAPCO Security Systems GEM-P3200 Programming Instructions...
Page 60
Direct Address 0922-0925 Zones Report Code (Group 3) Direct Address 0926-0929 Zones Report Code (Group 4) Direct Address 0930-0933 Zones Report Code (Group 5) Direct Address 0934-0937 Zones Report Code (Group 6) Direct Address 0938—0941 NAPCO Security Systems GEM-P3200 Programming Instructions...