KEYPAD CONFIGURATION MODE

This section will focus on configuring the GEM-RP1CAe2/GEM-K1CA Keypads. If there is more than one keypad in the system, we
recommend that either a GEM-RP1CAe2 or a GEM-K1CA keypad be used for programming.

KEYPAD INSTALLATION

Several types of keypads may be used with the GEM-P816: the GEM-RP1CAe2/GEM-K1CA, the GEM-RP2ASe2/GEM-K2AS, the
GEM-RP3DGTL/GEM-K3DGTL, and the GEM-RP4RFC/GEM-K4RF series (see WI1182). Each must be assigned an address num-
ber (1–7) and each requires its own configuration procedure (see CONFIGURING THE KEYPADS, which follows, and DIRECT AD-
DRESS KEYPAD AREA OPTIONS). At least 1 keypad must be used; only 1 is required for a single-area Commercial Burglary instal-
lation.
GEM-RP1CAe2/GEM-K1CA - is a 2-line combination fire/burglary/access keypad capable of supporting 4 EZM zones and a
PGM output. The GEM-RP1CAe2 or GEM-K1CA is recommended for programming. See "Important Note" on page 2
for more information regarding the buttons on the GEM-RP1CAe2/GEM-K1CA keypads.

CONFIGURING THE KEYPADS

A total of up to 7 keypads may be connected to the panel. GEM-RP1CAe2/GEM-K1CA, GEM-RP2ASe2/GEM-K2AS, GEM-
RP3DGTL/GEM-K3DGTL, and GEM-RP4RFC/GEM-K4RF series keypads may be intermixed but require different configuration pro-
cedures, as described below and in WI1182.
Configuring the GEM-RP1CAe2/GEM-K1CA Keypad
Each GEM-RP1CAe2/GEM-K1CA keypad must be configured for (a) keypad tactile beep; (b) entry sounder; (c) keypad address; (d)
compatibility number; (e) EZM address; and (f) zone response.
To enter the Keypad Configuration Mode:
1. Move jumper JP1 (located in the center of the control panel board) from Pins 1-2 (top two) to Pins 2-3 (bottom
two). NOTE: See Wiring Diagram at the end of this manual.
2. After about 15 seconds, the display will read "XX OUT OF SYSTEM", where XX indicates the keypad address.
3. Press
11123 R
Keypad Beep
Entry Sounder
Keypad Address
GEM-P816 Programming Instructions
and proceed as follows. (Repeat the following procedure for all keypads).
Keypad Tactile Beep
Upon entering the Keypad Configuration Mode, "KEYPAD BEEP ON" will be displayed,
indicating that the tactile beep, which sounds when any button is pressed, is on.
ON
To turn off the tactile beep, press the
tile beep on and off). Press
Entry Sounder
To turn off the keypad entry sounder during entry time, press
ON
will toggle the entry sounder on and off). Press
C
to exit.
Keypad Address
01
If more than one keypad is installed, each must be assigned a unique keypad
address (that is, no two keypads may be numbered alike):
Keypads must be numbered consecutively (missing numbers are not permitted)
To assign the keypad number, proceed as follows:
1. Enter the assigned keypad number 01–07, then press
number will be acknowledged by a short beep; an invalid number will be re-
jected by a long beep.
2. Press
to continue or press
R
U
U
button (the
to continue or press
R
C
to continue or press
R
C
to exit.
NAPCO Security Systems
R
NORMAL
KEYPAD
CONFIGURE
button will toggle the tac-
to exit.
U
U
(the
button
U
to save. A valid