KEYPAD CONFIGURATION MODE

This section will focus on configuring the GEM-RP1CAe2/GEM-K1CA Keypads. If there is more than one keypad in the system, only
Keypad No. 1 may be used for programming.

KEYPAD INSTALLATION

Several types of keypads may be used with the GEM-P816: the GEM-RP1CAe2/GEM-K1CA, the GEM-RP2ASe2/GEM-K2AS, the
GEM-RP3DGTL/GEM-K3DGTL, and the GEM-RP4RFC/GEM-K4RF series (see WI1182). Each must be assigned an address num-
ber (1–7) and each requires its own configuration procedure (see CONFIGURING THE KEYPADS, which follows, and DIRECT AD-
DRESS KEYPAD AREA OPTIONS). At least 1 keypad must be used; only 1 is required for a single-area Commercial Burglary instal-
lation.
GEM-RP1CAe2/GEM-K1CA - is a 2-line combination fire/burglary/access keypad capable of supporting 4 EZM zones and a
PGM output. The GEM-RP1CAe2 or GEM-K1CA is recommended for use as Keypad #1. See "Important Note" on page
2 for more information regarding the buttons on the GEM-RP1CAe2/GEM-K1CA keypads.
GEM-RP2ASe2/GEM-K2AS - is a utility LCD keypad combining several preset LCD words with a limited message line.
NOTE: Due to space constraints, available messages are abbreviated and will scroll automatically. (See WI1182).

CONFIGURING THE KEYPADS

A total of up to 7 keypads may be connected to the panel. GEM-RP1CAe2/GEM-K1CA, GEM-RP2ASe2/GEM-K2AS, GEM-
RP3DGTL/GEM-K3DGTL, and GEM-RP4RFC/GEM-K4RF keypads may be intermixed but require different configuration procedures,
as described below and in WI1182.
Configuring the GEM-RP1CAe2/GEM-K1CA Keypad
Each GEM-RP1CAe2/GEM-K1CA keypad must be configured for (a) keypad tactile beep; (b) entry sounder; (c)
keypad address; (d) compatibility number; (e) EZM address; and (f) zone response.
To enter the Keypad Configuration Mode:
1. Move jumper JP1 (located in the center of the control panel board) from Pins 1-2 (top two) to Pins 2-3 (bottom
two). NOTE: See Wiring Diagram on
2. After about 15 seconds, the display will read "XX OUT OF SYSTEM", where XX indicates the keypad address.
Keypad Beep
Entry Sounder
Keypad Address
X
GEM-P816 Programming Instructions
page
48.
3. Press
11123 R
(Repeat the following procedure for all keypads).
Keypad Tactile Beep
ON
Upon entering the Keypad Configuration Mode, "KEYPAD BEEP ON" will be displayed,
indicating that the tactile beep, which sounds when any button is pressed, is on.
To turn off the tactile beep, press the
tile beep on and off). Press
Entry Sounder
ON
To turn off the keypad entry sounder during entry time, press
will toggle the entry sounder on and off). Press
C
to exit.
Keypad Address
01
If more than one keypad is installed, each must be assigned a unique keypad
address (that is, no two keypads may be numbered alike):
!
Keypads must be numbered consecutively (missing numbers are not permitted)
!
Only Keypad No. 1 may be used for programming.
To assign the keypad number, proceed as follows:
1. Enter the assigned keypad number 01–07, then press
number will be acknowledged by a short beep; an invalid number will be re-
jected by a long beep.
2. Press
R
U
button (the
to continue or press
R
to continue or press
C
L
WI995C 2/04
GEMINI
# OF ZONES IN AREA
SYSTEM ARMED
# OF ZONES IN AREA 1
ENTER # ZONES XX
01/01/97 12:00AM
ENTER # ZONES X X
A
1 2
B
4
C
7 8 9 0
COMPUTERIZED SECURITY SYSTEM
NORMAL
KEYPAD
CONFIGURE
and proceed as follows.
U
button will toggle the tac-
to exit.
C
U
U
(the
button
R
to continue or press
U
to save. A valid
to exit.
NAPCO Security Systems
NEXT/YES
3
E
D
PRIOR/NO
5 6
F
AREA
G
R

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents