2. Disassembly
2-11-3. Sticking the SHEET EMI SIDE to the FRAME PWB
Purpose: To ensure conductivity between the two metal plates
BB17886-100
Use the center of the SW
UNIT plate as a guide to
lateral positioning. (Ensure
that it does not protrude.)
2-11-4. Sticking the SHEET EMI-BASE to the FRAME PWB/BASE TRIPOD
Purpose: To ensure conductivity between the two metal plates
BB17885-100
2-22
FinePix S9100/S9600 Service Manual
Fold the sheet into upper and lower halves and ensure that the
sheet does not protrude beyond either of the metal plates.
Adhesion location
Front-back: The corner where the plate begins
Left-right:
The edge of the notch in the plate