FinePix S9100/S9600 Service Manual
(13) Remove the BATT HOLDER connector.
(14) Remove the SYNCHRO TERMINAL connector.
Take care not to touch the main capacitor terminal as
this could result in an electric shock.
(15) Discharge the main capacitor. (To prevent electric
shock, check that it is fully discharged.)
(16) Remove the connector and disassemble the MAIN
PWB ASSY and DCST PWB ASSY.
(17) Remove the connector catches and pull off the FFC.
[Assembly]
Assemble by performing the disassembly procedure in
reverse order.
2. Disassembly
13
14
15
17
To BATT HOLDER
To SYNCHRO
TERMINAL
16
2-13