4. Adjustments
When [Adjustment OK!] appears on the screen, press the [Enter] key on the PC and make adjustment preparations in
accordance with the instructions from the adjustment software.
AF-Sensor vertical adjustment
Turn the AF-Sensor vertical adjustment screw.
Press the [Enter] of PC when the adjustment is completed.
OK!
Press [0]key of PC when you cannot complete the adjustment.
--> The [AF-Sensor horizontal adjustment Screen (Fig. 4-9-6)] appears.
<Step 6>
AF-Sensor horizontal Adjustment
(1) Change the S9000/S9500 AF-1mH Chart at a
distance of 1005+-5mm from the Zoom-Ring edge.
(2) Don't set the conversion lens yet.
(3) Set the zoom position to the side of the TELE edge.
When preparations (1) - (3) are complete,
press the [Enter] key.
Zoom Ring edge
| <--------------------------------------Center-------------------------------------->
|
CAMERA
= = =
< Setup for AF-Sensor H Adjustment >
--> The [AF-Sensor horizontal adjustment Screen (Fig. 4-9-7)] appears.
4-18
THRE1
=
146
MAX
=
195
MIN
=
129
1005+-5mm
FinePix S9100/S9600 Service Manual
MAX =
195
MIN
=
132
AF-1mH Chart
AF-1mH Cahrt
<Fig. 4-9-5>
<Fig. 4-9-6>