Networking Trunk Group/Route Advance Assignment - NEC Electra Elite IPK Programming Manual

Hide thumbs Also See for Electra Elite IPK:
Table of Contents

Advertisement

Document Revision 4
___________________________________________________________________________________
1-1-49
Networking Trunk Group/Route
Advance Assignment
General Description
Use this Memory Block to assign the function number of the Trunk Group to be used to
network an Electra Elite 48/192 system to another system by Tie lines or CO/PBX/
CTX lines.
Display
C l o s e d
N u m b e r
D a t a
B l o c k
N o .
0 1 ~ 1 6
4 9 : 0 1 = R T
T I M E
Programming Procedures
1 Go off-line.
D I
2 Press LK1 + LK1 +
3 Use dial pad to enter the Function Number for Closed Number Block 01 of the Trunk
Group or the Route Advance Block.
Use the following to enter data:
J
t o move the cursor left
L
t o move the cursor right
K
I
H
t o enter numeric data
~
to clear all data
G
4 Press
to write selected data and display the next Closed Number Block.
5 Repeat Steps 3 and 4 for each Closed Number Block. After data for the last Closed Number Block is written, the next Memory
Block is displayed.
6 Program the next Memory Block or press
Related Programming
M.B. Number
Memory Block Name
1-1-30
Route Advance Block Assignment
1-1-50
CO/PBX Outgoing Digit Add Assignment
3-03
Trunk-to-Trunk Group Assignment
Function Number 101
respectively) is assigned to Closed Number blocks.
___________________________________________________________________________________
2 - 64
F u n c t i o n
N o .
D I S P L A Y
to access the Memory Block.
E
to go back on-line.
1 32 (Trunk Group 1
3 2, respectively) or 201
~
~
Notes
2 32 (Route Advance Block 1
~
Electra Elite IPK
System Mode
1
Submode
1
Data No.
49
PC Programming
+BCS
Default Values
Not Specified
3 2,
~
Memory Blocks

Hide quick links:

Advertisement

Table of Contents
loading