1-1-63
Hold Recall Time Selection
(Exclusive)
General Description
Use this Memory Block to specify the time for Exclusive Hold Recall. When No Limit is
selected, Exclusive Hold Recall is not provided.
This Memory Block can be adjusted in 1-second intervals (R3000 or higher).
Display
D a t a
N o .
6 3 : H O L D
T I M E
Settings
LK 1
LK 2
0.5
1.0
Programming Procedures
1 Go off-line.
F C
2 Press LK1 + LK1 +
3 Press the corresponding CO/PBX line key to change the data option.
G
4 Press
to write the data and display the next Memory Block.
5 Program the next Memory Block or press
Refer to next page for R3000 or higher Programming Procedures.
___________________________________________________________________________________
Programming Manual
S e t t i n g
T i t l e
D a t a
R E C L
1 . 0
D I S P L A Y
LK 3
LK 4
LK 5
1.5
2.0
3.0
to access the Memory Block.
E
to go back on-line.
LK 6
LK 7
LK 8
5.0
8.0
(No Limit)