___________________________________________________________________________________
Display (R3000 or higher)
D a t a
N o .
3 7 : T R K
T I M E
Programming Procedures
1 Go off-line.
C G
2 Press LK1 + LK1 +
3 Use the dial pad to enter the Data Setting for Class 1.
Setting Data
G
00s~99s (e.g., 02s = 2s)
4 Press
to write the data and display the next Timer Class of Service.
5 Program the next Timer Class of Service or press
Related Programming
M.B. Number
Memory Block Name
4-71
Station to Timer Class of Service (R3000 or higher)
1.
When all trunks in a particular Trunk group are busy, the station user can dial an Access Code to queue on the
busy Trunk group. When a Trunk in that group becomes idle, the queued station is signaled.
2.
Telephone ports 1 and 2 are in Station to Timer Class of Service, Class 1 by default. All other ports are in Station
to Timer Class of Service, Class 2 by default (R3000 or higher)
3.
When a system is upgraded from R2500 or lower to R3000 or higher, the Trunk Queuing Timeout Selection is
reset to the default value during the upgrade process
___________________________________________________________________________________
2 - 50
T i m e r
C l a s s
S e t t i n g
1 ~ 4
T i t l e
D a t a
Q U E
1 = 1 0 s
D I S P L A Y
t o access the Memory Block.
E
to go back on-line.
Notes
.
.
Electra Elite IPK
Default Values
Class 1~4 = 10s
00s = No Limit
Memory Blocks