5
Press the lever 3 to remove the print
head $.
6
Disconnect all the connectors / from the
defective print head $.
In total, there are two connectors for CL4NX and
three connectors for CL6NX.
7
Connect all the connectors / to the new
print head.
CAUTION
Handle the print head with care.
Do not contaminate or scratch the sensitive print head
surface.
8
Install the new print head.
Install the print head so that it is locked with a click
sound.
9
Load the media and ribbon back if you remove them in step 4.
After the replacement
Clear the head counter value.
Refer to
Section 4.2 Counter Clear Mode
Check the print darkness.
Refer to
Section 4.5 Adjusting the Print Darkness