SATO CL4NX Service Manual page 43

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

6
Press the
/
buttons to select Calibrate
and then press the
7
Press the
/
buttons to select
Auto-calibrate and then press the
button.
8
Pass the media . below the media
sensor guide 3.
If you are using labels, remove the label from the
liner. Align it so that the media sensor does not
sense the I-mark (black mark).
9
Close the print head.
To get the correct adjustment result, adjust after you
have closed the print head.
10
Press the
/
buttons to select the type
of sensor to be adjusted.
• Gap + I-Mark: Perform the adjustment for both
the Gap sensor and I-mark sensor.
• GAP: Perform the adjustment for the Gap sensor.
• I-Mark: Perform the adjustment for the I-mark
sensor.
11
Press the right soft button or
start the sensor adjustment.
button.
button to
4 Checking and Performing Printer Adjustments