Fitting Back Plates To The Base Support Of The Back With Ergonomic Length Adjustment98 - Invacare Storm Service Manual

Hide thumbs Also See for Storm:
Table of Contents

Advertisement

8.11.5 Fitting back plates to the base support of the back with ergonomic length
adjustment
Requirements:
• 4 mm Allen key
Loosen the three Allen screws (1) but do not remove them completely.
Move the back plate (2) so that the large boreholes (3) are above the lower screw holes of the
centre back plate.
Tighten the three Allen screws slightly.
Repeat this on the second back plate.
Move the back of the seat to the rearmost position.
Slide the two lower slot nuts (4) in the left hand and right hand groove right down to the
bottom.
Push the upper ones so far to the top that the distances of the slot nuts coincide with the
distances of the screw holes.
Place the centre part of the back plate (3) on the backrest so that the four boreholes coincide
with the slot nuts (4).
Fit the four supplied Allen screws and tighten them.
Adjust the desired seat width with the help of the included centimetre scale.
Tighten the six Allen screws (1) firmly.