PROBLEM
Transmission
losing oil
Irregular
running
Parts lost
Batteries not
being charged
Short
charging
period
Mobility aid
runs too
slowly
24
OTHER
POSSIBLE
SYMPTOMS
CAUSE
None
Sealing ring on
drive shaft
defective
None
Drive shaft
movable or bent
None
Parts lost
None
Fuse burnt out,
cable defective
Batteries
defective
LEDs blinking
Charging unit
on charging
defective
unit
None
One of the
batteries could
be defective
None
Remote
defective
Batteries
defective
Documentation
SOLUTION
See chapter 8.17.1.
Replace
transmission if
sealing ring
defective.
See chapters 8.17.1 and
Check carbon
8.17.2
brushes for oil
wetting, replace
motor if brushes
wet
See chapter 8.17.1.
Check drive shaft,
replace
transmission if
defective.
Reattach parts
once found.
See chapters 8.3.5 and
Check cabling and
8.3.4
replace fuse
See chapter 8.3.2.
Replace batteries
See charging unit
Replace charging
operating manual
unit
See chapter 8.3.2.
Replace batteries
See chapter 8.4.1.
Replace remote
See chapter 8.3.2.
Replace batteries

Hide quick links: