Common Specifications - Mitsubishi FR - S500 Instruction Manual

Transistorized inverter
Hide thumbs Also See for FR - S500:
Table of Contents

Advertisement

4

.1.2 Common specifications

Control method
Output frequency range
Frequency setting resolution
Frequency accuracy
Starting torque
Acceleration/deceleration
time setting
Regenerative
Braking
torque (*2)
DC braking
Frequency
Analog input
setting
Digital input
signal
Start
STF, STR
signal
Alarm reset
Multi-speed selection
Second function selection
Output stop
Current input selection
External thermal relay
input
Jog signal
PID control valid
PU operation-external
operation switching
Selectable between Soft-PWM control and high carrier
frequency PWM control, V/F control or automatic torque
boost control selectable.
0.5 to 120Hz (starting frequency variable between 0 and
60Hz)
5VDC input: 1/500 of max. set frequency, 10V, 4 to
20mADC input: 1/1000 of max. set frequency. Digital input:
0.1Hz (less than 100Hz), 1Hz (100Hz or higher)
Analog input: Within 1% of max. output frequency
(25ºC 10ºC (77ºF±18ºF))
Digital input: Within 0.5% of set output frequency (when
setting dial is used)
150% (at 6Hz) during automatic torque boost control
0, 0.1 to 999s (may be set individually for acceleration and
deceleration), linear or S-pattern acceleration/deceleration
mode selectable.
0.1K, 0.2K ... 150%, 0.4K, 0.75K ... 100%, 1.5K ... 50%,
2.2K, 3.7K ... 20%,
Operation frequency (0 to 120Hz), operation time (0 to 10s),
operation voltage (0 to 15%)
0 to 5VDC, 0 to 10VDC, 4 to 20mA
Entered from control panel.
Forward and reverse rotation, start signal
automatic self-holding input (3-wire input) can
be selected.
Used to reset alarm output provided when
protective function is activated.
Up to 15 speeds can be selected. (Each speed
can be set between 0 and 120Hz, running
speed can be changed during operation from
the control panel.)
Used to select second functions (acceleration
time, deceleration time, torque boost, base
frequency, electronic overcurrent protection).
Instantaneous shut-off of inverter output
(frequency, voltage).
Used to select input of frequency setting signal
4 to 20mADC (terminal 4).
Thermal relay contact input for use when the
inverter is stopped by the external thermal relay.
Jog operation mode selection
Selection for exercising PID control
Used to switch between PU operation and
external operation from outside the inverter.
165
Use
Pr. 60 to
Pr. 63 for
selection.