Mitsubishi FR - S500 Instruction Manual page 160

Transistorized inverter
Hide thumbs Also See for FR - S500:
Table of Contents

Advertisement

Inspection
Description
Item
(1) Check with
megger
(across
main circuit
terminals
and ground
terminal).
General
(2) Check for
loose screws
and bolts.
(3) Check for
overheat on
each part.
(4) Clean.
(1) Check
conductors
Conductors,
for distortion.
cables
(2) Check cable
sheaths for
breakage.
Terminal
Check for
block
damage.
Inverter
Check
module
resistance
Converter
across
module
terminals.
(1) Check for
liquid
leakage.
(2) Check for
Smoothing
safety valve
capacitor
projection
and bulge.
(3) Measure
electrostatic
capacity.
(1) Check for
chatter
during
operation.
Relay
(2) Check for
rough
surface on
contacts.
Interval
Periodic*
Method
(1) Disconnect
all cables
from inverter
and measure
across
terminals R,
S, T, U, V, W
and ground
terminal with
megger.
(2) Retighten.
(3) Visual check.
(1), (2) Visual
check.
Visual check
Disconnect
cables from
inverter and
measure across
terminals R, S,
T P, N, and
across U, V,
W
P, N with a
meter with a
100
range.
(1), (2) Visual
check.
(3) Measure with
capacity
meter.
(1) Auditory
check.
(2) Visual check.
151
Criterion
Instrument
(1) 5M
or
500VDC
more.
class
(2), (3) No
megger
fault.
(1), (2) No fault.
No fault
Refer to page
Analog
153.
meter
(1), (2) No fault.
Capacity
(3) 85% or
meter
more of
rated
capacity.
(1) No fault.
(2) No fault.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents