Pu Contrast Adjustment; Pu Main Display Screen Data Selection - Mitsubishi FR - S500 Instruction Manual

Transistorized inverter
Hide thumbs Also See for FR - S500:
Table of Contents

Advertisement

2
.15.3

PU contrast adjustment

By setting the communication parameter n15 "PU contrast adjustment", you can
adjust the LCD contact of the parameter unit (FR-PU04). When using the FR-
PU04, adjust the numerical value to any brightness with the
define that brightness with the
Parameter
n15 (991) PU contrast adjustment
The parameter number in parentheses is the one for use of the parameter unit (FR-PU04).
CAUTION
When using the FR-PU04, you should press the
contrast setting.
2
.15.4

PU main display screen data selection

You can choose the main display screen of the parameter unit (FR-PU04).
Parameter
Name
PU main display
n16 (992)
screen data
selection
<Setting>
When you set 100 in n16, the monitor value changes depending on whether the
inverter is at a stop or running.
Output frequency
Output current
Alarm display
REMARKS
During an error, the output frequency at error occurrence appears.
During MRS, the values displayed are the same as during a stop.
Related parameters
Speed display
Pr. 37 "speed display" (refer to page 73)
WRITE
Factory
Name
Setting
Factory
Setting
0
0
During operation/stop
Output frequency
key of the parameter unit.
Setting
Range
58
0 to 63 Setting is enabled when Pr. 30 = "1"
key to store the LCD
WRITE
Setting
Range
0, 100
Setting is enabled when Pr. 30 = "1"
n16
During stop
Set frequency
Output current
Alarm display
134
/
keys and
Remarks
Remarks
100
During operation
Output frequency