Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi FR-S520-*K Series

  • Page 2 Quick Setting using Setting Dial The frequency and parameters etc. can be set with a few simple steps. Easily set values: turn quickly to greatly change the value, and turn slowly to finely ad- just the value. Accurate settings can be made with the new notch-type "clicking"...
  • Page 3: Table Of Contents

    Rotation speed(r/min) (For SF-JR 4P 0.75kW motor) Compact Design The foot print is the same as the Mitsubishi FREQROL-E520. (400V class installation area has been unified to 108mm(128m.) The height dimensions for all capacities have been unified to 128mm, making panel layout easier.
  • Page 4: Control Panel

    Control panel PU/EXT key: RUN display Changes the operation mode. PU=Control panel operation mode Shows the operation state. EXT=External operation mode RUN key: Forward run 3-digit LED monitor (Can be changed to reverse run Shows the parameter number with parameter settings.) and setting value.
  • Page 5: Model Configuration

    Type S5 2 0 0.1K No. of power supply Structure, communication Symbol Voltage Symbol Symbol Symbol Inverter capacity phases, etc. function, etc. 100V class None 3-phase input 0.1K None Enclosed type Indicates capacity 200V class Single-phase input RS-485 function provided (kW) Single-phase input Totally enclosed structure...
  • Page 6: General Specifications

    Self-cooling Approximately weight (kg) 1. The applicable motor indicates the maximum applicable capacity when using a Mitsubishi standard 4-pole motor. (Notes) 2. The rated output capacity is 230V for the 3-phase 200V output voltage, and 440V for the 3-phase 400V output voltage.
  • Page 7: Extermal Dimension Drawings

    External Dimension Drawings ( Unit: mm ) FR - S520 - 0.1K, 0.2K, 0.4K, 0.75K FR - S520 - 1.5K, 2.2K, 3.7K FR - S520S - 0.1K, 0.2K, 0.4K, 0.75K FR - S540 - 0.4K, 0.75 K, 1.5K, 2.2K, 3.7K FR - S520S - 1.5K FR-S510W-0.1K, 0.2K, 0.4K FR-S510W-0.75K...
  • Page 8: List Of Parameters

    List of Parameters Basic functions <default state> Function Parameter Name Setting range Minimum setting unit Default setting Torque boost 0~15% 0.1% 6%/5%/4% (Note 4) Maximum frequency 0~120Hz 0.1Hz 60Hz Minimum frequency 0~120Hz 0.1Hz Base frequency 0~120Hz 0.1Hz 60Hz Multi-speed setting (high speed) 0.1Hz 0~120Hz 60Hz...
  • Page 9: Explanation Of Parameters

    Explanation of Parameters "Pr." is the abbreviation of parameter. Pr.0 Torque boost Pr.7 Pr.8 Acceleration/deceleration time The motor torque in the low frequency area For the acceleration time, set the time to reach can be adjusted according to the load. the acceleration/deceleration reference frequency Pr.
  • Page 10: Alarm Displays

    Alarm Displays Main LED Fault class Main LED Fault class Main LED Fault class Protective function name Protective function name Protective function name display (Note 3) display (Note 3) display (Note 3) Accelerating Major fault Fan trouble Minor fault Major fault Communication error (Note 2) Constant speed Major fault...
  • Page 11 When considering this product for operation in special applications such as equipment or systems used in passenger transportation, medical, aerospace, nuclear energy, electric power, or submarine relay applications, please contact your nearest Mitsubishi sales department. Although this product was manufactured under strict quality control conditions, it is strongly advised to install safety devices to forestall serious accidents when used in facilities where a breakdown of the product is likely to cause a serious accident.

Table of Contents