Changing example Deflecting the meter (analog indicator) to full-scale (1mA) at the
POINT
The calibration parameters "C1" can be made to be ready by setting "1" (extended
function parameter valid) in Pr. 30 "extended function display selection".
Set the value of the calibration parameter C1 "FM terminal calibration".
In PU operation mode
1.
Press the
MODE
parameter setting mode.
2.
Turn the setting dial
"
" .
Pr. 30 must be set to "1".
(For details, refer to the instruction
manual (basic).)
3.
Press the
"
" .
4.
Turn the setting dial
calibration parameter C1 "FM
terminal calibration" appears.
5.
Press the
6.
If the inverter is at a stop, press the
key to start it. (The motor
RUN
need not be connected.)
7.
Turn the setting dial
adjust the indicator needle
to the desired position.
8.
Press the
Setting is complete.
preset frequency of 60Hz (for frequency setting, refer to the
instruction manual (basic).)
Operation
key to choose the
to show
key to show
SET
until the
key to enable setting.
SET
to
key.
SET
By turning the setting dial
Press the
key to return to the
SET
Press the
key twice to show the next parameter (
SET
MODE
SET
SET
RUN
+
-
SET
Flicker ... Parameter setting complete!!
, you can read another parameter.
indication (step 3).
112
Display
The parameter
number read
previously
appears.
RUN
PU
EXT
Analog indicator
).