Common Specifications - Mitsubishi FREQROL-U100 Instruction Manual

General purpose inverter
Table of Contents

Advertisement

• Common specifications
Control method
Sinusoidal wave PWM control *10
Output frequency range
0.5 to 120Hz (starting frequency fixed at 0.5Hz)
Frequency
Digital input
0.1Hz (less than 100Hz). 1Hz (100Hz and more) with key
setting
pad operations
"
resolution
Analog input
1/500 of maximum setting frequency
0
Within ±0.5% of set output frequency ( 10 to +50OC)
0
Digital input
.~
Frequency
with key pad operations
~
stability
Analog input
Within +1% of maximum output frequency (25°C±10°C)
g
Voltage/frequency characteristics Base frequency between 50 and 120Hz selectable
~
e
Torque boost
Manual torque boost 0 to 15% selectable
"
Acceleration/deceleration
0.0.1 to 999sec. selectable (acceleration/deceleration set
0
characteristics
separately)
u
0.1K. O.2K "'150% or more. OAK, 0.75K···100% or more.
Braking
Regenerative
*8
1.5K"'50% or more
torque
I
DC injection
3Hz or less Operation time, operation voltage adjustable
Stall prevention operation level
Operation current level (110 to 200%)selectable
"
Frequency setting signal
DC 0 to 5V
0
0
.~~
Input signat Starting signal
Forward/reverse rotation commanded separately
i;:'u
Output
Alarm
1b contact output
~.
signal
o~
>
Operation status
Output frequency. output current
*
11 selectable
~
Key pad
i5
Alarm
Alarm code when protective function has been activated.
-50-