Replacement Of Parts - Mitsubishi FR - S500 Instruction Manual

Transistorized inverter
Hide thumbs Also See for FR - S500:
Table of Contents

Advertisement

3

.3.7 Replacement of parts

The inverter consists of many electronic parts such as semiconductor devices.
The following parts may deteriorate with age because of their structural or physical
characteristics, leading to reduced performance and/or failure of the inverter. For
preventive maintenance, the parts must be changed periodically.
Part Name
Cooling fan
Smoothing capacitor in main circuit
Smoothing capacitor on control board
Relays
CAUTION
For parts replacement, consult the nearest Mitsubishi FA Center.
(1) Cooling fan
The cooling fan used to cool heat-generating parts such as the main circuit
semiconductors has a bearing whose life is said to be 10,000 to 35,000 hours. Hence,
the cooling fan must be changed every 2 to 3 years if the inverter is run continuously.
When unusual noise and/or vibration is noticed during inspection, the cooling fan must
be changed immediately.
Inverter Model No.
FR-S520-1.5K, 2.2K, 3.7K
FR-S520S-1.5K
FR-S540-1.5K, 2.2K, 3.7K
Standard Replacement
Interval
2 to 3 years
5 years
5 years
———
Fan Type
MMF-06D24DS BKO-C2416H07
MMF-06D24ES-FC4 BKO-CA1027H09
154
Description
Change (as required)
Change (as required)
Change the board (as required).
Change as required