Pa-
Func-
Indica-
rame-
tion
tion
ter
29
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
Name
Setting Range
0: Linear acceleration/
deceleration,
Acceleration/
1: S-pattern acceleration/
deceleration
deceleration A,
pattern
2: S-pattern acceleration/
deceleration B
Frequency
0 to 120Hz, - - -
jump 1A
Frequency
0 to 120Hz, - - -
jump 1B
Frequency
0 to 120Hz, - - -
jump 2A
Frequency
0 to 120Hz, - - -
jump 2B
Frequency
0 to 120Hz, - - -
jump 3A
Frequency
0 to 120Hz, - - -
jump 3B
Speed display 0, 0.1 to 999
Frequency
setting voltage
1 to 120Hz
gain frequency
Frequency
setting current
1 to 120Hz
gain frequency
Start-time
ground fault
0: Not detected
1: Detected
detection
selection
Up-to-
frequency
0 to 100%
sensitivity
Output
frequency
0 to 120Hz
detection
Output
frequency
detection for
0 to 120Hz, - - -
reverse
rotation
Second
acceleration/
0 to 999s
deceleration
time
Second
deceleration
0 to 999s, - - -
time
Second torque
0 to 15%, - - -
boost
Second V/F
(base
0 to 120Hz, - - -
frequency)
Minimum
Setting
Increments
1
0.1Hz
0.1Hz
0.1Hz
0.1Hz
0.1Hz
0.1Hz
0.1
0.1Hz
0.1Hz
1
1%
0.1Hz
0.1Hz
0.1s
0.1s
0.1%
0.1Hz
48
Factory
Cus-
Setting
Refer
tomer
<EC
To:
Setting
version>
0
71
- - -
72
- - -
72
- - -
72
- - -
72
- - -
72
- - -
72
0
73
60Hz
74
<50Hz>
60Hz
74
<50Hz>
0
78
<1>
10%
78
6Hz
79
- - -
79
5s
62
- - -
62
- - -
58
- - -
59

Hide quick links: