Mitsubishi FR - S500 Instruction Manual page 138

Transistorized inverter
Hide thumbs Also See for FR - S500:
Table of Contents

Advertisement

(5) Operation at alarm occurrence
Fault Location
Inverter fault
Communication error
(Communication from
RS-485 connector)
*3: Can be selected using the corresponding parameter (factory-set to stop).
(6) Communication error
Fault Location
Communication error
(Communication from RS-485 connector)
(7) Program example
To change the operation mode to computer link operation
Program
Line number
10 OPEN"COM1:9600,E,8,2,HD"AS #1
20 COMST1,1,1:COMST1,2,1
30 ON COM(1)GOSUB*REC
40 COM(1)ON
50 D$="01FB10000"
60 S=0
70 FOR I=1 TO LEN(D$)
80 A$=MID$(D$,I,1)
90 A=ASC(A$)
100 S=S+A
110 NEXT I
120 D$=CHR$(&H5)+D$+RIGHT$(HEX$(S),2)
130 PRINT#1,D$
140 GOTO 50
1000 *REC
1010 IF LOC(1)=0 THEN RETURN
1020 PRINT"RECEIVE DATA"
1030 PRINT INPUT$(LOC(1),#1)
1040 RETURN
General flowchart
Line number
10
I/O file initial
to
40
50
Send data processing
Data setting
to
Sum code calculation
Data send
140
Description
Inverter operation
RS-485
Communication
connector
Inverter operation
RS-485
Communication
connector
setting
Operation Mode
Communication
Operation
(RS-485 connector)
Stop
Continued
Stop/continued (*3)
Stop
Error Message
(Operation panel)
OPT
Initial setting of I/O file
Opening the communication file
ON/OFF setting of circuit control signals (RS, ER)
Interrupt definition for data receive
Interrupt enable
Send data setting
Sum code calculation
Addition of control and sum codes
Data send
Interrupt data receive
Interrupt occurrence during data receive
1000
Receive data processing
Data import
to
Interrupt
Screen display
1040
129
External Operation
Stop
Continued
Continued
Stop
Remarks
Error code is OPT
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents