Setting Dial Function Selection - Mitsubishi FR - S500 Instruction Manual

Transistorized inverter
Hide thumbs Also See for FR - S500:
Table of Contents

Advertisement

2
.6.2

Setting dial function selection

You can use the dial like a potentiometer to perform operation.
Parameter
Name
Frequency setting
53
operation selection
Using the setting dial like a potentiometer to perform operation
POINT
Set "1" (extended function parameter valid) in Pr. 30 "extended function display
selection".
Set "1" (setting dial potentiometer mode) in Pr. 53 "frequency setting operation
selection".
Operation example Changing the frequency from 0Hz to 60Hz during operation
1.
Mode/monitor check
Choose monitor/frequency monitor. (
The inverter must be in the PU operation mode.
(Press the
Pr. 30 must be set to "1".
Pr. 53 must be set to "1".
2. Press the
RUN
3. Turn the
setting dial
"60.0" appears. The flickering frequency is
the set frequency.
You need not press the
REMARKS
If flickering "60.0" turns to "0.0", the Pr. 53 "frequency setting operation selection"
setting may not be "1".
Independently of whether the inverter is running or at a stop, the frequency can
be set by merely turning the dial.
When the frequency is changed, it will be stored as the set frequency often 10 seconds.
Refer to
Factory
Setting
0
Operation
PU
key.)
EXT
key to start the inverter.
clockwise until
key.
SET
(page 82).
Setting
Range
0: Setting dial
frequency setting
mode
0, 1
1: Setting dial
potentiometer
mode
key)
MODE
RUN
83
Remarks
Setting is
enabled when
Pr. 30 = "1"
Display
RUN
PU
EXT
RUN
PU
EXT
Flickers for 3s.
2

Hide quick links:

Advertisement

Table of Contents