Setting The Transition Rate Display Mode; Making Settings Relating To Effects; Setting The First Keyframe When A Rewind Is Executed; Setting The Source And Destination Names - Sony MVS-3000 System User Manual

Multi format switcher system
Hide thumbs Also See for MVS-3000 System:
Table of Contents

Advertisement

3
Select the bus or function you want to assign from the
list on the right.
4
Press [Set].
Setting the Transition Rate Display
Mode
To determine whether to display transition rate values in
menus and on the control panel in frames or as timecode
values, select either of the following in the <Trans Rate
Display> group.
Frame: Displays in frames.
Timecode: Display as timecode (SS:FF).

Making Settings Relating to Effects

To make settings relating to the functions used when
carrying out keyframe effect operations, use the following
procedure.
1
Open the Engineering Setup >Panel >Operation
>Effect Mode menu (7326.2).
2
Make the following settings as required.
Effect recall mode: To select the state of the first
keyframe when an effect is recalled, select
[Recall] (the first keyframe is not recalled) or
[Recall&Rewind] (the first keyframe is recalled)
in the <Recall Mode> group.
Automatic first keyframe insertion: When an empty
register is recalled, to automatically insert a first
keyframe of the state at that point, turn [1st KF
Auto Insert] on.
Automatic effect saving: To automatically save an
effected when it is recalled after being edited, turn
[Effect Auto Save] on.
Keyframe duration default value: Press [Default KF
Duration], then enter the default value from the
numeric keypad window.
Setting the First Keyframe When a
Rewind is Executed
For P-Bus, GPI, and DDR/VTR timeline operations, to
execute the first keyframe when a rewind is carried out, set
each external device on in the <REWIND&1st KF> group
in the Effect Mode menu.
236
Operation Settings
Notes
When an effect is executed by pressing the [RUN] button
with this setting on, the first keyframe action is not
executed.
GPI: Settings for the GPI timeline.
P-Bus: Settings for the P-Bus timeline.
DDR/VTR: Settings for the VTR/disk recorder/Extended
VTR timeline.
Macro: Settings for the macro timeline.
Setting the Source and Destination
Names
To set the Source and Destination names used in the
control panel, use the following procedure.
Notes
Before carrying out these settings, it is necessary to set the
number of the S-Bus description name
1
In the <Source/Dest Name> group of the Engineering
Setup >Panel >Operation menu (7326), select the
names to be used from the following.
Sw'er Local: Source names set in the Xpt Assign
menu, and fixed bus names
S-Bus Descript: Description names set in the router
S-Bus Type + Num: Type + Num set in the router (In
this case, always eight characters.)
2
In the <Name Display Mode> group, select the method
of display in the source name displays.
Auto: Optimizes the display according to the number
of characters. Line breaks occur every four
characters, with up to the first twelve characters
shown in three lines.
4 Character: The first four characters appear.
To replace a name set in the Xpt Assign menu
with an S-Bus description name
Turn [S-Bus Name Link] on.
This has such effect that each time a description name is
changed on the router, the corresponding source name is
automatically changed. Thus, the same description name
can always be used both on the router and the switcher.
Even when [Sw'er Local] is selected, the same name as
when [S-Bus Descript] is selected can be displayed. The S-
Bus description name can also be displayed in the Xpt
Assign menu.
(1 p.
257).