Cross-Point Settings; Creating Cross-Point Assign Tables - Sony MVS-3000 System User Manual

Multi format switcher system
Hide thumbs Also See for MVS-3000 System:
Table of Contents

Advertisement

Function
Copy
Paste
Select all
Insert
Modify
Delete
Keyframe loop count setting
Effect duration setting
Keyframe duration setting
Delay setting
Constant duration mode on or off
Go to specified timecode
Go to specified keyframe
Set range
Return the button display to that
before effect was executed
Switch to numeric keypad input
mode
Go to first keyframe
Switch to shifted functions
Go to previous keyframe
Go to next keyframe
Execute effect
The functions of the buttons in the memory recall
section during effect editing are on two pages; to set
the functions of buttons on the second page, press the
[2] button in the <PageSelect> group in the button
area.
• Buttons in the memory recall section during
macro editing
Function
Undo
Pause setting
Auto insert mode on or off
Copy
Paste
Select all
Insert
Modify
Delete
Set range
Go to specified event
5
Press [Set] to confirm the setting.
To cancel an assignment
Select the corresponding button, then press [Clear].
To return all button assignments to the factory
Button indication
default state
COPY
Press [Default].
PSTE
ALL
INS

Cross-Point Settings

MOD
DEL
KF LOOP

Creating Cross-Point Assign Tables

EFF DUR
KF DUR
As cross-point assign tables, you can create a "main" table
DLY
and up to 14 other tables (table 1 to table 14). However,
you can only carry out assignment of the video and key
CNST DUR
combinations in the main table.
GOTO TC
GOTO KF
Creating the main table
FROM TO
In the main table, a pair consisting of a video signal and a
EXIT
key signal is assigned to each button number. You can also
assign the same signal to another button number at the
STOR
same time. Further, you can delete currently assigned
signals from the main table.
REWIND
1
SHFT
<<PREV
>>NEXT
RUN
2
Button indication
3
UNDO
PAUS
AUTO INS
COPY
PSTE
ALL
INS
MOD
DEL
4
FROM TO
GOTO EVNT
5
In the Engineering Setup >Panel >Xpt Assign menu
(7322) or Engineering Setup >Panel >Xpt Assign
>Table Button Assign menu (7322.1), press [Main, V/
K Pair Assign].
The Main, V/K Pair Assign menu (7322.5) appears.
The left of the status area shows the video and key
signal names, and source number currently assigned in
the main table. On the right is a list of the source
numbers and signals that can be assigned. When the
shift button is pressed, the number column is
distinguished by color.
Select the button number.
When assigning a video signal, press [Video] in the
<Assign> group. When assigning a key signal, press
[Key]. (You can select a video signal and a key signal
at the same time.)
Notes
[Video] and [Key] in the <Assign> group cannot be
turned off at the same time. One or the other is always
on.
Select the signal.
"IN33" to "IN48" and signal names relating to DME
and M/E-2 are disabled, even if selected.
Using the buttons in the <Xpt Assign> group, assign
the selected signal to the button number currently
selected in the main table.
223