Selectable actions for various trigger types
• When the trigger type is other than "Level"
(The x In M/E-x is the M/E bank number, the x in DSKx
is the DSK number, and the x in Keyx is the key
number).
When Target is M/E-x: Cut, Auto Trans, Keyx Cut,
Keyx Auto Trans, SS ? Recall, Keyx SS ? Recall,
Effect ? Recall, Effect ? Recall & Run, KF Run, KF
Stop, KF Rewind, KF Rev Run, No Action
When Target is P/P: Cut, Auto Trans, DSKx Cut, DSKx
Auto Trans, FTB Cut, FTB Auto Trans, SS ? Recall,
DSKx SS ? Recall, Effect ? Recall, Effect ? Recall &
Run, KF Run, KF Stop, KF Rewind, KF Rev Run,
No Action
When Target is Common/Setup: FM Src1 Field Freeze,
FM Src1 Frame Freeze, FM Src2 Field Freeze, FM
Src2 Frame Freeze, FM Src1 Freeze Off, FM Src2
Freeze Off, FM Src1 Clip Record, FM Src1 Clip
Stop, FM Src2 Clip Record, FM Src2 Clip Stop,
FM1 to FM8 Clip Cueup, FM1 to FM8 Clip Play,
FM1 to FM8 Clip Stop, User1 to 8 SS ? Recall,
User1 to 8 EFF ? Recall, User1 to 8 EFF ? Recall &
Run, User1 to 8 KF Run, User1 to 8 KF Stop, User1
to 8 KF Rewind, User1 to 8 KF Reverse Run, No
Action
• When the trigger type is "Level"
(The x in M/E-x is the M/E number).
When Target is M/E-x or P/P: Aspect, Bkgd A Side
Flags, Bkgd B Side Flags, No Action
When Target is Common/Setup: Format, Aspect, Level
Enable, No Action (for information about "Level
Enable," see "Notes" in
Input Settings" (1 p.
Notes
If "Format" is selected for "Action" when the format
converter is used on the switcher, you can set the
conversion format of the format converter for "FC Input 1-
4," "FC Input 5-8" and "FC Output 1-2."
Carrying out level settings
To set the low level and high level, first set the trigger type
to "Level," then use the following procedure.
1
In the Engineering Setup >Switcher >Device Interface
>GPI Input menu (7337.2), select the action to be set,
and press [H/L Set].
The H/L Set menu (7337.3) appears.
2
Select the setting to apply.
3
To apply the selection made in step 2 when the input
is the GPI high level, press [H Set]. To apply the
selection the input is low, press [L Set].
"Making Control Panel GPI
230).)
Notes
• When the action is "Format," these settings conflict
with the current settings, but after making the
settings, agreement is restored after a pulse change
or power off/on.
• When the Action is "Bkgd A Side Flags" or "Bkgd
B Side Flags," the levels are fixed, as follows.
High level: Off
Low level: On
To set the level for the format converter
1
Set "Action" to "Format" in step 5 of the procedure in
"Making Switcher Processor GPI Input Settings"
(1 p.
254).
The format converter list appears.
2
Select the format converter that you want to set from
the list.
3
In the <FC Input/Output> group, press [H Set] or [L
Set] to set the high level or low level, respectively.
Making Switcher Processor GPI
Output Settings
The switcher port must be assigned before using the
following procedure
("Assigning a Parallel Output Port"
(1 p.
232)).
1
In the Engineering Setup >Switcher >Device Interface
menu (7337), press [GPI Output].
The GPI Output menu (7337.4) appears.
2
Select the setting to apply.
3
In the <Trigger Type> group, select the trigger type.
(Rising Edge): The trigger causes the relay
contacts to be open-circuit or drives the output
high, and holds this state for the specified pulse
width.
(Falling Edge): The trigger causes the relay
contacts to be shorted or drives the output low, and
holds this state for the specified pulse width.
(Any Edge): Each time the trigger occurs, the
relay contacts are alternately closed or opened, or
the output is switched between high and low.
Status: Depending on the status, the relay contacts are
closed or opened, or the output is switched
between high and low.
No Operation: The trigger has no effect on the relay
state or output level.
Interfacing with External Devices
255