4.13 Installing the burner

This section explains how to install the burner.
Caution: System damage
through incorrect burner.
V Only use burners that conform to the
technical requirements of the boiler
(Æ see section 2.4, page 5).
z Close burner door and secure with four hexagon bolts
M16 x 140 at the positions shown.
z Tighten hexagon bolts evenly and diagonally.
z Cut or drill burner plate on site to match the blast tube
diameter.
z Drill holes for fastening the boiler using the burner
connecting flange as a template.
Predrilled burner plates are available on
request (optional extra).
z Screw burner plate onto the burner door (seal with GP
packing cord; diameter 10 mm).
z Screw the burner to the burner plate.
z Cut out insulating rings to match the blast tube
diameter.
z Fill the remaining gap between burner door insulation
and blast tube with the modified insulation rings.
z Connect the sight glass blower connection to the
burner to ensure the sight glass remains clear of
deposits.
Logano GE615 - We reserve the right to make any changes due to technical modifications.
1
2
Fig 36 Installing the burner
1
Sight glass
2
Blower connection