Fitting The Cross Bars - Buderus Logano GE615 Installation And Maintenance Instructions Manual

Calorific value forced draft sectional boiler
Hide thumbs Also See for Logano GE615:
Table of Contents

Advertisement

4
Installation

4.15.2 Fitting the cross bars

z Place top front cross bars onto the cast lugs and screw
in place with hexagon bolts (M8 x 12). The folded edge
on the front bar must face forwards.
z Place top rear cross bars onto the cast lugs and screw
in place with hexagon bolts (M8 x 12). The folded edge
of the rear cross bar must point towards the back.
z Place lengthways bars from the side onto the cross
bars and screw in place with self-tapping screws. The
folded edges of the of the lengthways bars must face
towards the back, while the slotted holes are
positioned towards the centre of the boiler.
z Screw each lower cross bar to the end section feet
with hexagon bolts.
32
Fig 40 Fitting cross bars and lengthways bars
1
2
3
4
5
6
Fig 41 Fitting the lower cross bars
1
2
Logano GE615 - We reserve the right to make any changes due to technical modifications.
Cast lug
Lengthways bar
Cross bar (top front)
Cross bar (top rear)
Lengthways bar
Cast lug
Cross bar (bottom front)
Cross bar (bottom rear)