R76-
TONER FULL state
160 ms < t1 < 0.8 sec
TNRSNS-N
t1
2.63 sec.
TONER LOW state
t1 > 0.8 sec.
TNRSNS-N
t1
2.63 sec.
• When the Toner Low state is detected 2 times consecutively, Toner Low is established.
• When the Toner Full state is detected 2 times consecutively, Toner Low is cancelled.
• When there is no change with the toner sensor for 2 cycles (2.63 sec. x 2) or more, then the
Toner Sensor Alarm is activated.
• The toner sensor is not monitored while the main (drum) motor is in a halt.
OF5750/5950 Series January 2001