4.3.19
Scanner Motor
1. Remove the scanner latch.
2. Remove the motor cable and unscrew
two screws (1) to remove the motor
along with the bracket.
Caution: Do not remove the four
screws* securing the motor.
3. Remove the bracket and ground plate by
unscrewing two screws.
Remove the Idle gear by releasing the
E-ring.
4. Remove the damper by unscrewing two
screws.
Caution: As a maintenance part, the
damper is available separately
from the motor. Keep the
damper without throwing it
away.
Precautions for Installation
1. When installing the damper, pay atten-
tion to its orientation and screw posi-
tions.
2. When installing the bracket and ground
plate, check for their positions.
OF5750/5950 Series January 2001
Scanner latch
Two screws
Ground plate
E-ring
Idle gear
Damper
Two screws
4 - 22
Four motor screws*
Bracket
Motor
Two screws 1
Bracket

Advertisement