4.
General
The section explains the procedures for replacement of parts, assemblies, and units in the
field. Only the disassembly procedures are explained here. For reassembly, reverse the
disassembly procedure.
4.1
Precautions for Parts Replacement
Do Not
Touch !
HIGH VOLTAGE
(1) Before starting to replace parts, remove the AC cord.
(a) Remove the AC cord in the following sequence:
1. Turn off ("o") the power switch of the machine.
2. Disconnect the AC inlet plug of the AC cord from the AC receptacle.
3. Disconnect the line cable from the machine.
(b) Reconnect the machine in the following procedure:
1. Connect the AC cord and line cable to the machine.
2. Connect the AC inlet plug to the AC receptacle.
3. Turn on ("l") the power switch of the machine.
OF5750/5950 Series January 2001
DANGER
You may be subjected to high-voltage electric shock by touching the
following parts without an insulating material:
a. High-voltage unit
PC board
b. Low-voltage
PC board
c. Contact ass'y
d. Power supply unit
* The high voltage risk may continue for about 3 days after power-off.
* Never touch the power supply unit pattern.
4 - 1