Oki OKIFAX 5950 Series Maintenance Manual page 447

Hide thumbs Also See for OKIFAX 5950 Series:
Table of Contents

Advertisement

(3) Registration motor
RMON-N
RMPH1-P
RMPH2-P
Stop
Rotation
(4) Drive control
Time T0 to T3 determines the motor speed, while the difference of phase direction
between phase signals DMPH1-P and DMPH2-P (RMPH1-P and RMHPH2-P) deter-
mines the rotation direction, DMON1-N signals control a motor coil current. According to
the polarity of the phase signal, the coil current flow as follows:
+38V ∅ SW ∅ motor coil ∅ SW ∅ resistor ∅ earth, or,
1)
+38V ∅ SW ∅ motor coil ∅ SW ∅ resistor ∅ earth
2)
The voltage drop across the reisistor is input to comparator, where it is compared with a
reference voltage. If an overcurrent flow occurs, a limiter operates to maintain it within a
certain fixed amount of current.
OF5750/5950 Series January 2001
T0
T1
T2
T3
Forward rotation
Hopping drive
Operation at normal speed: T0 to T3 = 1.016 ms
A3 - 19
Reverse rotation
Registration roller drive
R76-