2.9.2.2.4 Error Criterion
Registers the threshould value whether to transmit RTN or MCF signal when the error occurs
in received data.
ENTER Key
2.9.2.2.5 Attenuator
Adjusts the attenuation (dB) for the message send signal power level.
Adjusting value is 0 to 15dB in one dB steps.
ENTER Key
OF5750/5950 Series January 2001
S E T U P
1 7 D I S B I T 3 2
1 8 > E R R O R C R I T E R I O N
1 9 O F F H O O K B Y P A S S
ENTER/
Key
1 8 E R R O R C R I T E R I O N
V A L U E : 0 - 9 9
[ 5 5 ] %
E N T E R W H E N D O N E
10
1 8 E R R O R C R I T E R I O N
V A L U E : 0 - 9 9
[ 1 0 ] %
E N T E R W H E N D O N E
ENTER Key
S E T U P
2 0 N L E Q U A L I Z E R
2 1 > A T T E N U A T O R
2 2 T / F T O N E A T T .
ENTER/
Key
2 1 A T T E N U A T O R
V A L U E : 0 - 1 5
[ 8 ] D B
E N T E R W H E N D O N E
9
2 1 A T T E N U A T O R
V A L U E : 0 - 1 5
[ 9 ] D B
E N T E R W H E N D O N E
ENTER Key
2 - 34
T E C H N I C A L P R G . 1 8
1 > L O C A L T E S T
2 S E T U P
3 S Y S T E M R E S E T
'18' Key
400ms
T E C H N I C A L P R G . 2 1
1 > L O C A L T E S T
2 S E T U P
3 S Y S T E M R E S E T
'21' Key
400ms
COUNTRY CODE ≠ FRE
0 - 15dB
COUNTRY CODE = FRE
7 - 15dB