Oki OKIFAX 5950 Series Maintenance Manual page 316

Hide thumbs Also See for OKIFAX 5950 Series:
Table of Contents

Advertisement

Note:
*1: a indicates an alphanumeric character; n indicates a numeric character (0 to 9); h indicates a
hexadecimal number; and b indicates 0 or 1.
*2: Printed when the option board is mounted and if not, entry lines following this line are not
omitted.
*3: Lowercase letters can also be listed. This item reports MDL information for the PnP device ID
only.
This item can be up to 40 characters long.
*4: This item reports toner cartridge ID information (port read value).
Entry items shown below are printed.
CARTRIDGE
bbbb
*5: For the LAN board, the status of the LAN board at self diagnosis shall be recorded. (If the LAN
board is in the alarm state, the cause of the alarm is recorded.) When an HSP error occurs,
entry items shown below are printed.
HSP
NG
nn
nn=10:
Command was sent to the HSP card but its response was not returned within 5 seconds.
nn=20:
The Status Window did not show in the initial state 10 seconds after powering on.
nn=21:
Received the operation command during the POWER ON mode if it takes 3 seconds or more to
transfer to the operation mode after clearance of the initial synchronizing flag.
nn=22:
In the Reverse Data command, the HSK card could not transmit all the notification data from the
higher modules. (In case a communication error has occurred between the HSP and host.)
nn=00:
Others
*6: The result of ISDN board test, which is performed at self diagnosis, shall be lprinted. (Error
information at power-on shall also be listed partially.)
When an ISDN error occurs,entry items shown below are printed.
ISDN BOARD
NG
nn=01 Waiting for PC loading
The BOOT2 signal from the host side at the time of power on is set to PC loading mode.
nn=02 Board abnormality
The ISDN board program hash is NG upon power on.
nn=03 Board abnormality
The initial sequence between boards cannot be excuted in 10 seconds after power on. (The
status window does not indicate a normal value.)
nn=04 Board abnormality
The initial sequence of the ISDN LSI cannot be excuted upon power on.
(No response for the command, NG response)
nn=05 ISDN LSI abnormality
The result of ISDN LSI testing function is NG: (ROM/RAM test, Loop test)
OF5750/5950 Series January 2001
nn
6 - 10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Okifax 5750 series

Table of Contents