Routine Maintenance; Routine Maintenance Procedures For Ex9200 Switches; Handling And Storing Line Cards In Ex9200 Switches; Figure 76: Edges Of The Line Cards - Juniper EX9214 Hardware Manual

Hide thumbs Also See for EX9214:
Table of Contents

Advertisement

CHAPTER 25

Routine Maintenance

Routine Maintenance Procedures for EX9200 Switches

Purpose
Action
Related
Documentation

Handling and Storing Line Cards in EX9200 Switches

Copyright © 2015, Juniper Networks, Inc.
Routine Maintenance Procedures for EX9200 Switches on page 231
Handling and Storing Line Cards in EX9200 Switches on page 231
Maintaining Line Card Cables in EX9200 Switches on page 235
Maintaining Power Supplies in EX9200 Switches on page 235
Maintaining the Air Filter in EX9200 Switches on page 236
Maintaining Host Subsystem in EX9200 Switches on page 237
Maintaining the Fan Tray in EX9200 Switches on page 239
For optimum performance of an EX9200 switch, perform preventive maintenance
procedures.
Inspect the installation site for moisture, loose wires or cables, and excessive dust.
Make sure that airflow is unobstructed around the switch and into the air intake vents.
Check the status-reporting devices on the craft interface—System alarms and LEDs.
Inspect the air filter at the left rear of the switch, replacing it every 6 months for optimum
cooling system performance. Do not run the switch for more than a few minutes without
the air filter in place.
Maintaining the Air Filter in EX9200 Switches on page 236
Components in the line cards are fragile. To avoid damaging the line cards, follow the
procedures in this topic. The procedures use the following terms to describe the four
edges of the line cards (see
Figure 63 on page
205):