CHAPTER 34

Electrical Safety Guidelines and Warnings

General Electrical Safety Guidelines and Warnings

Copyright © 2015, Juniper Networks, Inc.
General Electrical Safety Guidelines and Warnings on page 303
Action to Take After an Electrical Accident on page 304
Prevention of Electrostatic Discharge Damage on page 305
AC Power Electrical Safety Guidelines on page 307
AC Power Disconnection Warning on page 309
DC Power Electrical Safety Guidelines on page 310
DC Power Disconnection Warning on page 312
DC Power Grounding Requirements and Warning on page 313
DC Power Wiring Sequence Warning on page 314
DC Power Wiring Terminations Warning on page 316
Multiple Power Supplies Disconnection Warning on page 318
TN Power Warning on page 318
This topic applies to hardware devices in the EX Series product family, which includes
EX Series switches, the EX Series Redundant Power System (RPS), and the XRE200
External Routing Engine.
This topic also applies to hardware devices in the QFX Series and to OCX1100 switches.
WARNING:
Certain ports on the device are designed for use as intrabuilding
(within-the-building) interfaces only (Type 2 or Type 4 ports as described in
GR-1089-CORE) and require isolation from the exposed outside plant (OSP)
cabling. To comply with NEBS requirements and protect against lightning
surges and commercial power disturbances, the intrabuilding ports must not
be metallically connected to interfaces that connect to the OSP or its wiring.
The intrabuilding ports on the device are suitable for connection to
intrabuilding or unexposed wiring or cabling only. The addition of primary
protectors is not sufficient protection for connecting these interfaces
metallically to OSP wiring.
303