Powering The Magnum 6K32F Series Managed Switch - GarrettCom Magnum 6K32F Installation And User Manual

Industrial managed switch
Hide thumbs Also See for Magnum 6K32F:
Table of Contents

Advertisement

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (07/10)
The optional 23" brackets and the ETSI (21") brackets each come as a pair in a
package, along with the necessary screws for attaching the brackets to the sides of the
Magnum Switch unit. They must be ordered as separate line items.
3.3.2
Rack-mounting, Reverse version of the Magnum 6K32FR &
6K32FRC
The optional Reverse Magnum 6K32FR/FRC Model has all of the cabling
(Ethernet cabling, power cabling and console port cabling) connectors in the rear, and the
status LEDs in the front. The status LEDs that are co-incident with the ports are still
present, and a second or dual set of LEDs are used for status visibility in the front of the
unit, showing the same data.
There are three options of brackets available to mount in the standard 19"
frame, 23" frame, or ETSI (21") frame. The 19" brackets are included with each unit, the
other two may be purchased as separate options.
With each bracket type, there are three different mounting options as shown in Fig. 3.3.2.
The case of the Magnum 6K32F has mounting holes prepared for each of the mounting
arrangements. Users may choose the mounting arrangement most
suitable for their installation.
Fig 3.3.2 Reverse Magnum 6K32F Series
3.4

Powering the Magnum 6K32F Series Managed Switch

The Magnum 6K32F Series Switches incorporate an internal universal power
supply and have a recessed male IEC connector for the AC power cord at the left-rear. A
manual power ON-OFF switch is adjacent. A six-foot 115 VAC 60 Hz standard power
cord is supplied with each unit shipped within the United States and Canada.
The auto-ranging power supply supports installation environments where the
AC voltage is from 90 to 260 volts with a power input frequency between 47 and 63 Hz.
www GarrettCom com
.
.
34
Important
Note:
For
adequate
convection
cooling,
always
install a
6K32FRC
switch with
a minimum
of 1/2U
(0.875") air
space above
and below.