GarrettCom magnum 6kl Installation And User Manual

GarrettCom magnum 6kl Installation And User Manual

Managed edge switch
Table of Contents

Advertisement

Magnum 6KL
Managed Edge Switch
Hardware
Installation and User Guide
www GarrettCom com
.
.

Advertisement

Table of Contents
loading

Summary of Contents for GarrettCom magnum 6kl

  • Page 1 Magnum 6KL Managed Edge Switch Hardware Installation and User Guide www GarrettCom com...
  • Page 2 If problems are experienced with Magnum 6KL Switch products, consult Section 6, Troubleshooting. Copyright © 2009 GarrettCom, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from GarrettCom, Inc. Printed in the United States of America GarrettCom, Inc.
  • Page 3 Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 Federal Communications Commission Radio Frequency Interference Statement This equipment generates uses and can radiate frequency energy and if not installed and used properly in strict accordance with the manufacturer's instructions, may cause interference to radio communication.
  • Page 4: Table Of Contents

      INTRODUCTION ................. 7     Inspecting the Package and Product ............ 7     Product Description - Magnum 6KL Managed Edge Switch ....8     2.2.1 Packet Prioritization, 802.1p QOS ..........9     2.2.2 Frame Buffering and Flow Control ..........10  ...
  • Page 5 Magnum 6KL Managed Edge Switch Installation and User Guide 11/09     5.1.11 6KL4-2MSC2RJ, 6KL4-2MST2RJ (Slot C) ......37     5.1.12 6KL4-2SSC2RJ (Slot C) ............38     5.1.13 6KL4-2SL2MLC, 6KL4-1SL3MLC (Slot C) ......38     5.1.14 6KL4-1ML1SLC2RJ (Slot C) ............ 38  ...
  • Page 6: Specifications

    Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 SPECIFICATIONS Technical Specifications Performance Filtering / Forwarding Rate: Ethernet (10Mb): 14,880 pps Fast Ethernet (100Mb): 148,800 pps Gigabit Ethernet (1000Mb): 1,488,000 pps Switching Processing Type: Store and Forward with IEEE 802.3x full-...
  • Page 7 Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 1000BASE-LX, full-duplex, multi-mode (50, 62.5μm cable) - 550m 1000BASE-LX, full-duplex, single-mode (9μm cable) - 5km 1000BASE-ZX, full duplex, single-mode (9μm cable) - >70km Fiber Multi-mode connector types supported: Fiber Port, MTRJ-type (plug-in): SFF Fiber multi-mode 100BASE-FX...
  • Page 8 Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 DC Power Supply (Internal, floating ground) DC Power Connector: IEC-320 type, male recessed from cord exiting unit 125VDC Power Input nominal (range 88 to 150VDC) 250VDC Power Input nominal (range 160 to 300VDC)
  • Page 9: Ordering Information

    Configuration Options: (see following pages) Each Magnum 6KL base unit may be configured with a choice of 1 modular slot (Slot C) and fixed Gigabit ports (Slot B) in addition to the fixed RJ45 ports in Slot A. www GarrettCom com...
  • Page 10 Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 Following modules can be configured in Slot C only (Slot C is 10/100 RJ-45 or 100Mb Fiber only) Magnum 6KL (Slot C) Port Modules: 6KL4-RJ45 adds four 10/100 copper ports...
  • Page 11 Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 Following modules can be configured in Slot B only Magnum 6KL (Slot B) Gigabit Port Modules: 6KL-2GCU adds two auto-negotiating 10/100/1000Mb copper ports 6KL-2GSFP adds two SFP pluggable open transceiver ports for user selectable SFP...
  • Page 12: Introduction

    Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 INTRODUCTION Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery.
  • Page 13: Product Description - Magnum 6Kl Managed Edge Switch

    Designed for use in industrial applications such as factory floors and control cabinets, industrial video surveillance systems with PoE, power utility substations, tariffed carrier field facilities, or transportation and oil and gas, the rugged Magnum 6KL handles stressful workloads (mixes of bursty data traffic and priority streaming traffic) as well as harsh environmental conditions.
  • Page 14: Packet Prioritization, 802.1P Qos

    High performance features include non-blocking unicast traffic speed on all ports and 802.1p QoS Traffic Prioritization. Magnum 6KL switches are “plug-and-play” and are designed for use in connecting edge devices such as PLCs, IEDs and PoE video cameras with upstream switches and routers where a mix of bursty data traffic and priority streaming traffic for video surveillance and cell-tower applications are present.
  • Page 15: Frame Buffering And Flow Control

    When the Magnum 6KL Switch detects that its free buffer queue space is low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the devices sending it packets to cause “flow control”.
  • Page 16: Magnum 6Kl Managed Edge Switch Installation And User Guide

    Managed Network Software for Magnum 6KL Magnum 6KL comes with licensed MNS-6K software or MNS-6K-SECURE, which allow the user to configure the Magnum 6KL as a Managed Switch and implements security features and other software enabled features. (NOTE: Magnum 6KL managed switch will work with MNS-6K Rel v4.1.6 firmware or higher version only, or MNS-6K-SECURE v14.1.6 firmware or higher...
  • Page 17: Features And Benefits

    Features and Benefits Managed switching for high performance Ethernet LANs Magnum 6KL Switches provide unicast non-blocking (all ports can run at full speed at once) performance with standard Managed Network Software. They are typically used in LAN traffic centers with up to 8 100Mb +2 Gigabit ports for backbone connections, where managed network services are desired.
  • Page 18: Applications

    They provide the flexibility of 100Mbps fiber and copper ports as well as single or dual Gigabit (1000Mb) ports, with industry-standard LAN management software. Magnum 6KL Switches are easily used in a variety of applications including client/server computing, secure VLAN- performance upgrades to departmental networks, and stream traffic for VOIP and audio/video applications.
  • Page 19 The different locations can be easily connected together with the Fiber ports supported by the Magnum 6KL Switch. A main NT-server in a secure area protected from earthquake or fire hazards can be connected to the full duplex Gigabit Fiber port.
  • Page 20 SNMP monitor. Fig 2.5b Magnum 6KL equipped with S-Ring in redundant ring solution The Magnum 6KL Managed Edge Switch equipped with a mix of copper and fiber ports provides an economical and seamless solution to many requirements. The...
  • Page 21 In a fast growing secure video environment, the 6KL is a reliable and secure solution. The modular design of the Magnum 6KL, provides a wide range of copper/fiber options to meet requirements. The Gigabit uplink for storage or broadband uplink allows the telecom user a very effective solution to store their sensitive data securely.
  • Page 22: Installation

    If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and uncompromised earthing path. This section describes installation of the Magnum 6KL Switches, as well as connection of the various Ethernet media types. Locating Magnum 6KL Switches For vertical DIN-Rail mounting, see Section 3.3...
  • Page 23: Connecting Ethernet Media

    Connecting Twisted Pair (CAT3, CAT5, UTP or STP) 3.2.1 The RJ-45 ports of the Magnum 6KL can be connected to the following two media types: 100BASE-TX and 10BASE-T. CAT 5 cables should be used when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used.
  • Page 24: Connecting Twisted Pair (Cat5E Or Better, Utp Or Stp)

    Connecting Twisted Pair (CAT5e or better, UTP or STP) 3.2.2 The RJ-45 Gigabit ports of the Magnum 6KL can be connected to the media types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair (STP) balanced cable. The CAT 5E or better 100-ohm UTP or shielded twisted pair (STP) balanced cable is recommended to use when making 1000BASE-TX connections.
  • Page 25: Gigabit Sfp (Small Form-Factor Pluggable) Transceivers

    Due to its compact, hot pluggable characteristics, SFPs are becoming a very popular choice for various applications. The small-chassis Magnum 6KL is designed for industry-standard Gb-SFPs for user selection of the SFP gigabit media type as desired.
  • Page 26: Din-Rail Mounting The Magnum 6Kl

    Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 Find the Transmit (TX) and Receive (RX) markings on the SFP transceiver to verify the top side of it. Some of the transceiver marks arrow sign for up. Position the SFP transceiver correctly before insertion, and then insert the SFP transceiver carefully, until the transceiver connector snap into the place in the socket connector.
  • Page 27: Mounting Dimensions For 6Kl With Metal Brackets

    Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 To release the 6KL from the DIN-Rail mounting, simply lift up on the bottom of the unit, disengaging the DIN rail bracket from the DIN rail. Once the bottom of the 6KL is rotated out, the DIN-Rail bracket is not engaged and the 6KL can be moved up and out, free of the DIN-Rail mounting.
  • Page 28 Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 Fig 3.3.1b Panel / Wall Mounting position 2: The unit is mounted using the brackets as shown in the illustration above. The spacing for the mounting screws into the supporting wall or panel is a rectangle 2.81 x 8.58 inches (7.14 x 21.79 cm)
  • Page 29: Powering The Magnum 6Kl Managed Edge Switch

    Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 Powering the Magnum 6KL Managed Edge Switch The DC internal power supply supports installation environments where the DC voltage is from 10 to 300 volts depending on the model selected. The power consumption will range from about 10 up to 15 watts, depending on the port quantity and types in the configuration..
  • Page 30: Alarm Contacts For Monitoring Internal Power, And Software Traps

    Magnum MNS-6K Software User Manual. The Alarm Contacts are on the front left area (next to the Console port) of the Magnum 6KL unit and are green in color as shown in the picture. Fig 3.5a Alarm Contacts:...
  • Page 31: Connecting The Console Terminal To Magnum 6Kl

    11/09 Connecting the Console Terminal to Magnum 6KL Use a (RJ45) “null modem” cable to connect the Magnum 6KL Console Port (the RJ45 Console port on the 6KL Switch) to your PC, so that your PC becomes the 6KL Console Terminal.
  • Page 32: Operation

    All ports can communicate to all other ports in a Magnum 6KL, but local traffic on a port will not consume any of the bandwidth on any other port.
  • Page 33: Auto-Cross(Mdix) And Auto-Negotiation, For Rj-45 Ports

    When Magnum 6KL RJ-45 copper ports are set for auto-negotiation and are connected to another auto-negotiating device, there are 4 different speed and F/H modes possible depending on what the other device supports.
  • Page 34: Flow-Control, Ieee 802.3X Standard

    The Path Delay Value (PDV) bit-times must account for all devices and cable lengths within that domain. For Magnum 6KL Fast Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.
  • Page 35: Power Budget Calculations For 6Kl Modules With Fiber Media

    An important feature of the Magnum 6KL is the use of Port Modules for flexible mixed-media connectivity to RJ-45 copper and various fiber media. The first four ports (1,2,3 & 4) of the Magnum 6KL Switches are fixed RJ-45 copper ports with dual-speed 10/100Mbps auto-negotiating capability. Additionally the switch can accept...
  • Page 36: 6Kl Module Led Designations

    Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 5.1.1 6KL Module LED designations PWR LED= ON, when Power is being supplied to the unit. RJ45 (Standard) 1= ON (100Mb), OFF (10Mb) 2= ON (Link), BLINKING (Activity) 3= ON (Full Duplex), OFF (Half Duplex)
  • Page 37 Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 MTRJ (Fiber) 1= ON (Link), BLINKING (Activity) 2= ON (Full Duplex), OFF (Half Duplex) LC (Fiber) 1= ON (Link), BLINKING (Activity) 2= ON (Full Duplex), OFF (Half Duplex) SC (Fiber)
  • Page 38: 6Kl4-Rj45, 4 X 10/100Mb Rj45 (Slot C)

    Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 5.1.2 6KL4-RJ45, 4 x 10/100Mb RJ45 (Slot C) The 6KL4-RJ45 4-port Copper module provides four 10/100Mb switched RJ- 45 ports. The 10/100Mb switched ports normally (as a default setting) are independently N-way auto-negotiating and auto-crossover (MDIX) for operation at 10 or 100Mb speed in full- or half-duplex mode.
  • Page 39: 6Kl4-4Mlc, 4 X Multimode Lc (Slot C)

    The 6KL4-4MLC fiber ports are Small Form Factor (SFF) LC Multimode connectors used primarily in 100Mbps fiber-to-the-desktop links. When installed in a Magnum 6KL Series Switch, it supports fiber optic cable distances up to the IEEE- standard 100Mbps distance limits, i.e., typically 2km at full-duplex and 412m at half- duplex.
  • Page 40: 6Kl4-2Slc2Rj, 6Kl4-2Slcl2Rj (Slot C)

    (UTP) and shielded twisted pair (STP) cable connections. When installed in a Magnum 6KL Series Managed Switch, the copper ports support the standard distance of 100m on each port.
  • Page 41: 6Kl4-2Mt2Rj, 2 X Multimode Mtrj / 2 X Rj45 (Slot C)

    Fiber ports. This option utilizes a ST-type “twist-lock” fiber optic connection. The 10Mb ST-fiber ports allow the user to connect their legacy 10Mb network to the Magnum 6KL Series switch. It supports distances according to the 10Base-FL standard (up to 2km for...
  • Page 42: 6Kl4-4Ssc, 6Kl4-4Sscl (Slot C)

    (UTP) and shielded twisted pair (STP) cable connections. When installed in a Magnum 6KL Series Managed Switch, the copper ports support the standard distance of 100m on each port.
  • Page 43: 6Kl4-2Ssc2Rj (Slot C)

    (UTP) and shielded twisted pair (STP) cable connections. When installed in a Magnum 6KL Series Managed Switch, the copper ports support the standard distance of 100m on each port.
  • Page 44: 6Kl4-1Mlc3Rj, 1 X Lc Multimode / 3 X Rj45 (Slot C)

    Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 5.1.15 6KL4-1MLC3RJ, 1 x LC Multimode / 3 x RJ45 (Slot C) The 6KL4-1MLC3RJ 4-port Fiber/Copper module provides one 100Mb Multimode LC Fiber port, supporting distances up to 2km and three 10/100Mb switched RJ45 ports.
  • Page 45: P6Kl4-Rj45, 4 X Poe Rj45 (Slot C)

    The PoE ports in Magnum 6K’s with 48VDC power input act as a pass- through, so the 48VDC power input source to the Magnum 6KL must be strong enough to provide power to the 6K switch and to all 4-RJ45 ports with PD devices connected (up to 15 watts per PoE port).
  • Page 46: 6Kl-2Gcu, 2 X Gigabit Rj45 (Slot B)

    1310nm (2km), single-mode 1310nm (10km and 25km) and single-mode 1550nm (40km and 70km) fiber options. (see Sec. 1.2 of this manual for available part numbers) The 1000Mb Gigabit SFP fiber-port modules on the Magnum 6KL are normally set (factory default) to operate at AUTO mode for best fiber distance and performance.
  • Page 47: Troubleshooting

    However, if you are unsure of the procedures described in this section or if the Magnum 6KL Switch is not performing as expected, do not attempt to repair the unit; instead contact your supplier for assistance or contact GarrettCom Customer Support.
  • Page 48: Return Material Authorization (Rma) Procedure

    Date of installation Failure symptoms, including a full description of the problem. GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details).
  • Page 49: Shipping And Packaging Information

    GarrettCom. This warranty will not be effective if, in the opinion of GarrettCom, the product has been damaged by misuse, misapplication, or as a result of service or modification other than by GarrettCom.
  • Page 50: Appendix B: Dc Power Input

    11/09 APPENDIX B: DC Power Input B1.0 Specifications for Magnum 6KL Switches, DC Power at 12, 24, –48, 125 and 250VDC Power input Each Magnum Model 6KL Managed Switch requires DC power input, at 12, 24, 48, 125 and 250VDC nominal. The wide range of DC power input types qualifies this product for use in 12, 24, 48, 125 and 250VDC applications in different industries.
  • Page 51 Magnum 6KL Switch. The DC terminal block on the Magnum 6KL Managed Switch is located on the left front of the unit and is equipped with four (4) screw-down lead posts. The power terminals are identified as positive (+) and negative (-), and they are electrically floating inside the unit so that either may be grounded by the user if desired.
  • Page 52 4 inches apart, with the first one located within 6 inches of the terminal block. B5.0 OPERATION Operation of Magnum 6KL Switches with the optional -48VDC, 12VDC, 24VDC, 125VDC or 250VDC dual-source power input is identical to that of the standard single-source DC-powered models. B6.0 TROUBLESHOOTING Please refer to Section 6.0 for troubleshooting...
  • Page 53: Appendix C: Internal Dc Dual-Source Power Input Option

    Magnum 6KL -48VDC, 12VDC, 24VDC, 125VDC and 250VDC models with this Dual-Source option are identical to those listed in the Magnum 6KL Edge Switches Installation and User Guide, including Appendix B “Internal DC Power Supply Option”...
  • Page 54 This section describes the proper connection of the -48VDC, 12VDC and 24VDC dual source leads to the power terminal block on the Magnum 6KL Switch (shown in Figure above) The terminal block is located on the left front of the unit next to the Alarm terminal block and is equipped with four (4) screw-down lead posts.
  • Page 55 Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 negative (A-), and the secondary power terminals as negative (B-), positive (B+). The chassis is earth/ground (GND). The connections for 125 and 250VDC are made by a fixed cord exiting the 6KL unit.
  • Page 56: Appendix D: Field Installation Instructions For Slot C Module

    1/4” Nut Driver ESD Wrist strap or equivalent 6KLx Module Kit: A Magnum 6KL-Series Port Module kit comes in an anti-static bag containing: 6KLx module board (1) Matching module faceplate panel (1) 5/8” standoffs (4), or (6) for 5.5” PCB #4-40 x 3/16”...
  • Page 57 Magnum 6KL Managed Edge Switch Installation and User Guide 11/09 Step 1d: Remove panel (blank shown) Step 2a: Add new panel Step 2b: Remove Main PCB screws Step 2c: Install stand-offs Step 3a: Locate Main PCB connector Step 3b: Guide module into panel...

Table of Contents