GarrettCom Magnum 6K16-Series Installation And User Manual

GarrettCom Magnum 6K16-Series Installation And User Manual

Managed fiber switch
Table of Contents

Advertisement

Magnum 6K16-Series
Managed Fiber Switch
Two 6K16s mounted side-by-side on Tray
Magnum 6K16V mounted vertically
Hardware
Installation and User Guide
www GarrettCom com
.
.
i

Advertisement

Table of Contents
loading

Summary of Contents for GarrettCom Magnum 6K16-Series

  • Page 1 Magnum 6K16-Series Managed Fiber Switch Two 6K16s mounted side-by-side on Tray Magnum 6K16V mounted vertically Hardware Installation and User Guide www GarrettCom com...
  • Page 2 NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc. Important: The Magnum 6K16-Series Managed Fiber Switch contains no user serviceable parts.
  • Page 3 Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com...
  • Page 4: Table Of Contents

    Magnum 6K16V, Managed Fiber Switch ........10 2.2.1b Magnum 6K16, Managed Carrier Class Switch ......11 2.2.1c Magnum 6K16-Series family (6K16 and 6K16V), At a glance. 12 2.2.2 Eight-port SFF fiber modules , 100Mb fiber ......13 2.2.3 Eight-Port Copper Module, 6K8-RJ45 ........14 ..
  • Page 5 Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06) OPERATION ..................40 Switching Functionality ..............40 Status LEDs ..................41 Up-link Manual Switches set as (=) , for RJ-45 port only ....41 Auto-Cross(MDIX) and Auto-negotiation, for RJ-45 ports....41 Flow-control, IEEE 802.3x standard ..........
  • Page 6 Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06) Revisions 04/06: minor updates as PoE modules option added on Sec 5.2.10/11 10/05: minor updates as MDIX support added on all RJ-45 port modules 02/05: minor updates and tweaks on LC port module 07/04 : 6K16 carrier class managed switch has been added with 6K16V 01/04 : Added Section 3.5 (Alarm Contacts) and 3.7.1 (Console Port pins)
  • Page 7 Magnum 6K16-Series Managed Fiber Switch Installation and User Guide 04/06) THE MAGNUM LINE Ethernet connectivity products "Designed and Manufactured in the USA" Overview GARRETTCOM, INC. OFFERS THE PREMIUM-QUALITY MAGNUM™ LINE OF ETHERNET LAN CONNECTIVITY PRODUCTS WITH INDUSTRY-STANDARD FUNCTIONALITY AND BUILT-IN FIBER CONFIGURABILITY.
  • Page 8 Magnum 6K16-Series Managed Fiber Switch Installation and User Guide 04/06) 8 OR 9-PORT AND 4 OR 5-PORT PERSONAL HUBS, W/ MAN. UP-LINK MEDIA CONVERTERS, 10MB AND 100MB SERIES ALL MEDIA COMBINATIONS, INCL. FIBER ST, SC, MM., SINGLE MODE THE “X-LINE” OF CONFIGURABLE MIXED MEDIA PRODUCTS:...
  • Page 9: Specifications

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) SPECIFICATIONS Technical Specifications Performance Filtering / Forwarding Rate: Ethernet(10Mb):14,880 pps Fast Ethernet(100Mb): 148,800 pps Gigabit Ethernet(1000Mb): 1, 488,000 pps Switching Processing Type: Store and Forward with IEEE 802.3x full- duplex flow -control, non-blocking...
  • Page 10 Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Fiber Single-mode connector types: Fiber Port, SC-type: Fiber optic single-mode, 100BASE-FX Fiber Port, LC-type Fiber SFF single-mode, 100BASE-FX Fiber Port, 1000BASE-FX, GBIC modules LEDs: Per Port (one set at the port, one set on rear top) 6K16V only...
  • Page 11 Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) For DC internal power supplies at –48VDC, 24VDC and 125VDC, including Dual Source options ( for continuity of operation when either of the , see Appendices B and C. DC input sources are interrupted)
  • Page 12: Ordering Information

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Ordering Information Magnum Managed Fiber Switch (16 ports max) MODEL DESCRIPTION Magnum 6K16V -Magnum 6K16V Managed Fiber Switch, base unit for vertical mounting. Worldwide AC power. May be configured with a selection of 10/100/1000 fiber and copper port connector types, 16 total ports max.
  • Page 13 Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) fiber ports connector GBPMV-2OTX Two-port Gigabit 6K module for 6K16-Series Switches, provides two GBIC open transceiver port for a user-selectable GBIC transceiver module GBPMV-COTX One slot Gigabit 6K module for 6K16-Series Switches, uses one 6K16-...
  • Page 14 Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Gigabit (1000Mb) module option for Magnum 6K16V “G+2” module, w/one GBIC transceiver and four 10/100 RJ-45 6KP5-G4RJ connectors “G+2” module, w/one GBIC transceiver and two 100Mb 2km FX SC 6KP3-G2SC...
  • Page 15 Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 6K PoE Modules with 48VDC Pass-Through Configuration options: only one A, B or C module slot of 6K-Series switch with 48VDC power input may be configured with a PoE Modules New P6KP8-RJ45 8 port PoE module for 6ks with 48vdc PS, w/eight PoE power source 10/100 auto-negotiating auto cross RJ-45 ports.
  • Page 16: Introduction

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Introduction Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery.
  • Page 17: Product Description - Magnum 6K16-Series (6K16/6K16V)

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Product Description - Magnum 6K16-Series (6K16/6K16V) agnum  6 K16-Series Managed Switches, available as Magnum 6K16 and 6K16V models, and equipped with 16 modular ports, is specially designed to focus on two different aspects of Ethernet markets to meet their needs and requirements.
  • Page 18: Magnum 6K16V, Managed Fiber Switch

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Security with control via Web and command line interface (CLI). For high availability LANs using ring topologies, Spanning Tree Protocol, Link-Loss-Learn and S-Ring are available. See the Managed Networks Software (MNS-6K) and S-Ring datasheets for additional details on the comprehensive set of software programs and options.
  • Page 19: 2.2.1B Magnum 6K16, Managed Carrier Class Switch

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) choice of popular DC options or industry standard AC internal input. The plug-n-play Magnum 6K16V managed fiber switch, should be mounted vertically using the vertical mounting brackets which come with the unit or by using the DIN- RAIL-KIT (optional) for Din rail mounting.
  • Page 20: Magnum 6K16-Series Family (6K16 And 6K16V), At A Glance

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) requirement of this space. Magnum 6K management features not only allow the easy monitoring of the switch through SNMP, but also protect the network through its security features of port-security, SNMP3, VLAN etc. The redundant feature through STP, RSTP...
  • Page 21: Eight-Port Sff Fiber Modules , 100Mb Fiber

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Media Copper & Fiber Same Port Module can be 10,100 or 1000Mb Same e, Industrial Suitable for Applications Telco, Offic Utility,Industrial,Outdoors Operation Plug-n-Play Same MDI/MDIX on RJ-45 Same Note- The Redundant S-Ring feature for self-healing ring sold separately.
  • Page 22: Eight-Port Copper Module, 6K8-Rj45

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) HDX type of Fast Ethernet devices). There are three LED’s per fiber port. The Link (LK) LED indicates “ready for operation” on that port when lit, the F/H LED indicates operation in full-duplex mode when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving Activity on the port.
  • Page 23: New Poe(Power Pass-Through), Model P6Kp8-Rj45, 10/100Mb 8-Port

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) or 100Mb speed and full- or half-duplex mode per-port as per user requirement. (See Magnum MNS-6K Software Manual for details info.). 2.2.4 New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8-...
  • Page 24: Four-Port 10 Mb And 100Mb Mm Fiber St Modules

    The default setup on 10Mb, fiber module is half-duplex, which allows the Magnum 6K16-Series Switch to connect to any 10Mb hub or media converter or almost any other device with a 10Mb fiber Ethernet port. The default setting of 100Mb, fiber module is full duplex.
  • Page 25: Gigabit (1000Mbps) Port Modules

    2.2.7 Gigabit (1000Mbps) port modules The Magnum 6K16-Series offered a wide option Gigabit speed with multiple choice for the modular slot. While up to two Gigabit modules (maxm.) can be configured in the modular slot. The Gigabit port option for the modular slot comes in couple of different configuration.
  • Page 26: Frame Buffering And Flow Control

    When the Magnum 6K16-Series Switch detects that its free buffer queue space is low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the devices sending packets to cause “flow control”.
  • Page 27: Managed Network Software ( Mns-6K ) For Magnum 6K8-Series

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 2.2.10 Managed Network Software ( MNS-6K ) for Magnum 6K8-Series Magnum 6K8-Series’s come with licensed MNS-6K Firmware (Rel 3.2), which allows to configure the Magnum 6Ks as a Managed Switch and other Software enabled features.
  • Page 28: Managed Network Software ( Mns-6K ) For Magnum 6K8

    Features and Benefits Managed switching for high performance Ethernet LANs Magnum 6K16-Series Switches provide non-blocking (all ports can run at full speed at once) performance with standard Managed Networks Software (MNS-6K) included. They are typically used in LAN traffic centers with 16 100Mb or 8+2 Gigabit ports for backbone connections, where managed network services are desired.
  • Page 29: Applications

    They provide the flexibility of 100Mbps fiber and copper ports as well as single or dual Gigabit(1000Mb) ports, with industry-standard LAN management software. Magnum 6K16-Series Switches are easily used in a variety of applications including client/server computing, secure VLAN- performance upgrades to departmental networks, and stream traffic for VOIP and audio/video applications, or a very diversified combination of mixed media in Industrial floor applications..
  • Page 30 The different locations can be easily connected together with the Fiber ports supported by the Magnum 6K16-Series Switch. A main NT-server in a secure area protected from earthquake or fire hazards can be connected to the full duplex Gigabit Fiber port.
  • Page 31 Ethernet units . The entire spread network will be manageable to provide easy, detectable, uninterrupted support through a viewable SNMP monitor. The Magnum 6K16-Series Managed Fiber Switch equipped with the mix of copper and fiber ports provides an economical and seamless solution to the requirements.
  • Page 32 Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) In another application, in a Telco environment, 12 port Nebs Example 3. compliant, -48VDC operated managed switch is required to meet the fiber and copper connection to store the sensitive datas. The switch must be snmp enabled and managed to easily manage the whole setup.
  • Page 33: Installation

    For AC power input, locate an AC receptacle that is within six feet (2 meters) of the intended Magnum 6K16-Series site. The rugged metal case of the Magnum 6K16- Series will normally protect it from accidental damage in a lab or workplace setting.
  • Page 34: Connecting Fiber Optic St-Type, "Twist-Lock

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) IEEE Standard Media Type Max. Distance Port Module Fiber: Fiber 220m ( ft) 100BASE-FX GBIC-SXSC sgl.m Fiber GBIC-LXSC Fiber 2.0km (6,562 ft) 100BASE-FX 6K6-MSC, -MST sgl.m Fiber 18.0km (95K ft)
  • Page 35: Connecting Twisted Pair

    Connecting Twisted Pair (RJ-45, CAT3, CAT5, Unshielded or Shielded) The RJ-45 ports of the Magnum 6K16-Series can be connected to the following two media types: 100BASE-TX and 10BASE-T. CAT 5 cables should be used when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used.
  • Page 36: Connecting Gigabit Media Using Gbics

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) NOTE : It is recommended that high quality CAT. 5E cables (which work for both 100 Mb and 1000Mb) be used whenever possible in order to provide flexibility in a mixed-speed network.
  • Page 37 Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) the top when the 6K16V is installed on a DIN Rail. To install the 6K16V with the DIN-Rail brackets and latches attached to it, hold the 6K16V in the vertical position with the bottom out, and with the top moved in toward the DIN-Rail.
  • Page 38: Mounting Dimensions For 6K16Vwith Metal Brackets

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) The DIN-Rail mounting brackets and latches are optional and need to be ordered as separate items, e.g Model # DIN-RAIL-VRM 3.3.1 Mounting Dimensions for 6K16Vwith metal brackets Each Mangum 6K16V is supplied with metal mounting brackets and screws to mount the unit securely.
  • Page 39: Rack-Mounting Options For Telco And Etsi Standard

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 3.3.2 Rack-mounting options (Magnum 6K16) for Telco and ETSI Standard Magnum 6K16, a carrier class focused managed switch can be mounted as rack-mount using the following kit options offered for this product –...
  • Page 40: Powering The Magnum 6K16-Series Managed Fiber Switch

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Powering the Magnum 6K16-Series Managed Fiber Switch The Magnum 6K16-Series Switches incorporate an internal universal power supply and have a recessed male IEC connector for the AC power cord at the left-rear. A manual power ON-OFF switch is adjacent.
  • Page 41: 6K16-Series Port Module (6Kpm) Installation

    Magnum MNS-6K Software User Manual. (Chapter 19th). The Alarm Contacts are on the front left area (next to the DC power source) of the Magnum 6K16-Series unit and is green in color as shown in the picture. 6K16-Series Port Module (6KPM) Installation...
  • Page 42 Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) contains (Daughterboard (Bigger) and Granddaughter board (smaller), three 5/8 stand offs for Granddaughter board, 6 standoff for daughter Board, nine #4-40 Pan-Head screws along with Front panel face plate package. The Front panel faceplate package includes 2 retainer brackets and four #2-56 flat head screws.
  • Page 43: Installing 6Kpm Cards In The Magnum 6K16-Series

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) When the chassis top cover has been removed, the interior of the unit is exposed. Looking down into the Magnum 6K16-Series unit, notice that there are individual PM installation spaces and female latch (white) connectors provided on the main board along with four stand-off’s for each 6KPM card position.
  • Page 44 Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) screw down tightly with the three 5/16 stand-off (male) on the top of the Granddaughter board The 5/16 stand off has been used to place the daughter board on the top of the granddaughter board and latch it securely.
  • Page 45 Figure 3.6.2f: Securely latching up 6KPM Cards into a Magnum 6K16-Series NOTE: All 6KPM slots need not be filled in order for the Magnum 6K16-Series unit to be operational. When leaving 6KPM slots empty, always use a face plate (Magnum 6K8-BLNK) to cover the slot opening in the front panel.
  • Page 46: Removing 6Kpm Cards

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) installed inside of the top cover. Step 8. Once all 6KPM cards have been installed (including faceplates for empty slots), the chassis cover should be replaced. Make sure the chassis cover is aligned properly before securing the enclosure.
  • Page 47: Connecting A Management Console Terminal To Magnum 6K16- Series

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Connecting a Management Console Terminal to Magnum 6K16- Series Use a DB-9 “null modem” cable (use on any serial port)or “one DB-9 and one USB” ( USB port on the laptop) null modem cable to connect the Magnum6K16-Series Console Port (the RS-232 port on the 6K16-Series Switch) to the your PC, so that your PC becomes the 6K16-Series’s Console...
  • Page 48: Magnum 6K16-Series Managed Fiber Switch Installation & User Guide

    10 or 100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and network performance. All ports can communicate to all other ports in a Magnum 6K16-Series, but local traffic on a port will not consume any of the bandwidth on any other port.
  • Page 49: Status Leds

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Status LEDs For Magnum 6K16-Series models (6K16/6K16V) : : Power LED, ON when external power is applied to the unit. : Steady ON, Link status for 10 Mbps and 100Mbps operation.
  • Page 50 The Path Delay Value (PDV) bit-times must account for all devices and cable lengths within that domain. For Magnum 6K16-Series Fast Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.
  • Page 51: Flow-Control, Ieee 802.3X Standard

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Flow-control, IEEE 802.3x standard Magnum 6K16-Series Switches incorporate a flow-control mechanism for Full-Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a long burst of activity causes the switch to save frames until its buffer memory is full. This is most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the 10Mb port is unable to keep up.
  • Page 52 Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) The following data has been collected from component manufacturer’s (Agilent’s and Lucent’) web sites and catalogs to provide guidance to network designers and installers. Fiber Speed, Std. Wave Cable X’mitr R’cvr...
  • Page 53: Inspecting The Package And Product

    Refer to Chapter 5 for specific return procedures. 6KPM Module Description An important feature of the Magnum 6K16-Series is the use of Port Modules for flexible mixed-media connectivity to RJ-45 and fiber media. Since the Magnum 6K16-...
  • Page 54: 6Kp6-Rjmst, Combo Module

    100Mb combo module with the exception of 10Mb speed at the ST fiber module. The ST-connector functions as a fiber optic transceiver to support 10BASE-FX network segments. When installed in a Magnum 6K16-Series Managed Switch, the copper port supports the standard distance 100m on each port and the fiber port supports fiber optic cable distances up the IEEE-standard 10Mbps distance limits, i.e., typically 2km at full-...
  • Page 55: 1B 6Kp4-F10St, 4@10Mb Multi-Mode Fx-St "Twist Lock" Module47 5.2.1C 6Kp4-Flstfx, Module

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 5.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module The Magnum 6KP4-F10ST 6KP4-RJ10MST, is a 10Mb multi-mode 4 Port@ 10Mb ST Fiber Port fiber module with 4 ST- Fiber ports. All four fiber...
  • Page 56: 6Kp6-Rjmsc Fiber Connector

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) network to the Magnum 6K16-Series switch. They also provide a convenient way for the half duplex hub to connect to the switch through 10Mb fiber ports. Whereas the 100Mb ST fiber module, allow to connect the 100Mb demand of Switch devices. It supports distances according to the 10Base-FL standard i.e, 2Km distance for multi-mode fiber.
  • Page 57: 6Kp6-Rjsscl Connector

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) module of the 6K16-Series Switch supporting four Copper and two single-mode fiber network segments. The 6KP6-RJSSC, when installed in a Magnum 6K16-Series Switch operates on copper at the 100m distance. The Fiber is single-mode and cable lengths can be as much as 25+ Km (see Power Budget, Section 4.5)
  • Page 58: 6Kp8-Mtrj, Small-Form-Factor

    100Mb full-duplex, whereas the bottom two ports multi-mode ST-Fiber support 10Mb half-duplex. This combo module provides more flexibility to the user to connect their legacy 10Mb fiber as well as 100Mb to the Magnum 6K16-Series Switch. When installed in a Magnum 6K16-Series Switch, the 100Mb MTRJ connector...
  • Page 59: 6Kp8-45Mt, Fx , Mtrj Small-Form-Factor

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) i.e., typically 2km at full-duplex and 412m at half-duplex. The 10Mb Multi-mode ST- Fiber connector supports the standard fiber optic distance limit of 2Km at Full and Half- duplex both.
  • Page 60: 6Kp8-45Lc, Combo Factor

    The 6KP8-45LC is equipped with 4 10/100 RJ-45 ports and 4 LC ( Small form factor) multi-mode fiber ports. When installed in a Magnum 6K16-Series Switch, it supports the standard distances as per mentioned on 5.2.8. and the LEDs also acts similarly as mentioned above.
  • Page 61: New Poe(Power Pass-Through), P6Kp8V-Rj45 (Mdix), 8-Port

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) shielded twisted pair (STP) cable connections. The 6KP8-RJ45 module is equipped with a Media Dependent Auto-Crossover (MDI-X) switch, which controls all ports for cascaded connection. This feature eliminates the need for a special twisted pair crossover cable when connecting to a hub or another switch.
  • Page 62: 6Kp8-45-2Mt, Fx , Mtrj Small-Form-Factor

    10/100 RJ-45 ports and two ACTIVITY FULL/HALF 100Mb MTRJ fiber ports. When installed in a Magnum 6K16-Series Switch, it supports the standard distances as mentioned on 5.2.3. and the LEDs also act similarly. 5.2.12a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode...
  • Page 63: Gbic-Sxsc Gigabit Fiber(1000Mb), Multi-Mode Sc Connector55 5.2.13A Gbic-Lxsc Gigabit Fiber (1000Mb), Sc Connector

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) When installed in a Magnum 6K16-Series Switch, it supports the standard distances as mentioned on 5.2.4. and the LEDs also act similarly. 5.2.13 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connector The Magnum GBIC-SXSC is a multi-mode Gigabit fiber connector equipped with SC type connectors and can be easily snapped in and out.
  • Page 64: 6Km-Blnk

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 1@ 1000Mb Fiber SC + 2@ 100Mb SC The two Giga port has been offered as GBPM-2OTX (fiber or RJ-45), whereas the single Gigabit module comes in flavor of G+4(10/100 RJ-45 ports) or G+2 (100Mb fiber ports) as shown below in the above figure.
  • Page 65: Troubleshooting

    However, if you are unsure of the procedures described in this section or if the Magnum 6K16-Series Switch is not performing as expected, do not attempt to repair the unit; instead contact your supplier for assistance or contact GarrettCom Customer Support.
  • Page 66: When Calling For Assistance

    Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) When Calling for Assistance Please be prepared to provide the following information. A complete description of the problem, including the following points: a. The nature and duration of the problem;...
  • Page 67: Shipping And Packaging Information

    Testing and repair of product that is not under warranty will result in a customer (user) charge. Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions: Package the unit carefully. It is recommended that you use the original container if available.
  • Page 68 B1.0 SPECIFICATIONS FOR MAGNUM 6K16-SERIES SWITCHES, DC POWER Magnum 6K16-Series models, for –48V and 24V DC & 125VDC and 5V Power input Each Magnum Model 6K16-Series Managed Switch (DC option) requires a DC power source, for 24VDC, -48VDC and 125VDC option or 5VDC input. The wide range of power input qualifies this product for use in 24VDC, -48VDC as well as 125VDC or 5VDC environments.
  • Page 69 24VDC/125VDC/5VDC leads) to the DC power terminal block on the Magnum 6K16- Series Switch. The DC terminal block on the Magnum 6K16-Series Managed Switch is located on the left front of the unit and is equipped with three (3) screw-down lead posts.
  • Page 70: Appendix C: Internal Dc Dual-Source Power Option

    48V or –48V supply must be connected to the post labeled “+”. An ON-OFF manual switch is optional for DC power. This can be used to cut off power connections and as a RESET for the Magnum 6K16-Series Switch. B4.1 UL Requirements for DC-powered units Minimum 18AWG cable for connection to a Centralized DC power source.
  • Page 71 Two separate sources, each at 115 - 150 VDC With the exception of the dual DC input power connections and the power supply, all specifications and configuration options for the Magnum 6K16-Series -48VDC, 24VDC and 125VDC models with this Dual-Source option are identical to those listed in the Magnum 6K16-Series Fiber Switches Installation and User Guide, including Appendix B “Internal DC Power Supply Option”...
  • Page 72 Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely tightened. The 24VDC & 125VDC terminal block on Magnum 6K16-Series’s is similar to that described in the –48VDC information above. www GarrettCom com...
  • Page 73 Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) C5.1 UL Requirements The following must be adhered to in order to conform to UL requirements: Minimum 18 AWG cable for connection to a Centralized DC power source. Minimum 14 AWG cable for connection to earthing wiring.

Table of Contents