Summary of Contents for GarrettCom Magnum 6K25e
Page 1
Magnum 6K25e Gigabit Fiber Switch Hardware Installation and User Guide www GarrettCom com...
Page 2
NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc. Important: The Magnum 6K25e Managed Fiber Switch contains no user serviceable parts.
Page 3
Magnum Gigabit Fiber Switch Installation and User Guide (10/07) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed GarrettCom, Inc. below: 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com...
Technical Specifications............... 1 Ordering Information ................4 INTRODUCTION.................. 7 Inspecting the Package and Product............. 7 Product Description - Magnum 6K25e Managed Fiber Switch ... 7 2.2.1 Magnum 6K25e and 6K25eR chassis........... 9 2.2.2 Eight-port SFF fiber modules 100Mb fiber........9 2.2.3...
Page 5
APPENDIX A: WARRANTY INFORMATION ......... 57 APPENDIX B : INTERNAL DC POWER SUPPLY OPTIONS....58 APPENDIX C: INTERNAL DC DUAL-SOURCE POWER OPTION ..60 Revisions Rev A 10/07 : This rev. is the initial release of the 6K25e manual. www GarrettCom com...
Page 6
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) The Magnum Line INDUSTRIAL NETWORKING PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" OVERVIEW GarrettCom, Inc. offers premium-quality Magnum™ line INDUSTRIAL conectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Industrial Grade, Carrier Class, POWER UTILITY and OEM applications where reliability is a primary consideration.
Page 9
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) For DC internal power supplies at –48VDC, 24VDC and 125VDC, including Dual Source options ( for continuity of operation when either of the DC input sources , see Appendices B and C.
Magnum 6K25eR-125VDC: Same as 6K25eR except the power input is 125VDC Configuration Options: Each Magnum 6K25e and 6K25eR base unit has four port module slots. The first three (A,B,C) may be one of the modules below, one (slot D) may only be a Gigabit module.
Page 11
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) For Gigabit module configuration options GBPM-COTX One slot Gigabit 6K module for 6K25e Switches, uses one 6K25e slot and provides one GBIC open transceiver port for a user-selectable GBIC transceiver...
Page 12
New PI6KP6-RJ10ST “4+2” port PoE module for 6ks with 48vdc PS, w/four POE power source and two 10 Mb 2km sm FL ST connectors GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or model offerings without notice. www GarrettCom com...
Industry-standard IEEE 802.1p QOS prioritization is included, providing high performance switching services for both “smooth” streaming and “bursty” data traffic. The Magnum 6K25e has up to 25 ports capacity, all of which may be configured as fiber ports, but still offers a space-saving rack-mount chassis that is only 1U (1.70in.
Page 14
Fiber Switches are easy to install and use. Addresses of attached nodes are automatically learned, maintained and aged out, adapting the switching services to network changes. LEDs provide status information on each port. The Magnum 6K25e provides high performance plug-and-play hardware operation, 802.1p packet prioritization in hardware, and industry-standard managed networks software functionality, all in convenient 1U rack-mount packages.
GBICs. The port types configurable using the 4 slots allows the 6K25e to efficiently serve a large variety of applications, especially using fiber media. The Magnum 6K25e port modules are normally factory installed, but may be changed or added in the field.
Using the 6K25e’s MNS software, the user may select full- or half-duplex mode per-port through set-up of the software (See Magnum 6K25e MNS Software Manual) for the flexibility to adapt to any FDX or HDX type of Fast Ethernet devices).
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) eliminate the need of cross-over cable. On the model 6K8-RJ45 module, there are four LEDs for each port, two in the connector and two separate. The LK (Link) LED indicates “ready for operation” on that port when lit.
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) ordering information Sec.1.2. for all the various PI6K PoE modules option. The LEDs on 6KP8-RJ45- PoE module are slightly different compared to regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the PoE LED is ON when connected properly to a 803.af compliant PD device on that port.
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) (MDIX) feature to eliminate the use of cross-over cable, and the two fiber ports operate at 100Mbps full-duplex (default). User mode control per port through the MNS software is also the same.
3, 4. 7, 8 are not present. The default setup on the 10Mb fiber module is half-duplex, which allows the Magnum 6K25e Switch to connect to any 10Mb hub or media converter or almost any other device with a 10Mb fiber Ethernet port. User mode control per port through the MNS software is the same as the other 6K25e modules.
When the Magnum 6K25e Switch detects that its free buffer queue space is low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the devices sending packets to cause “flow control”.
Managed Network Software (MNS-6K ) for Magnum 6K25e-Series Magnum 6K25e’s come with Rel3.7 licensed MNS-6K software, which allows the user to configure the Magnum 6K25e as a Managed Switch and implements security features and other software enabled features. (NOTE: Magnum 625e managed switch will work with Rel 3.7 firmware or higher...
Modular design for port flexibility, in a 1U space-saving rack-mount package The 1U Magnum 6K25e chassis has 4 slots for port configurations. Family of 4, 6 or 8 port modules allow the user to select the desired mix of port types & speeds. The port modules are normally factory installed and tested, but may be changed in the field.
Page 24
RJ-45 ports are MDI/MDIX supported The RJ-45 modules are equipped with MDI/MDIX capability to eliminate the use of cross-over cable. The Auto-MDIX capability allow the Magnum 6K25e to cascade any Hub, switches or media converters with normal straight cable. SFP Gigabit module being supported on Slot D Due to design constrains, Slot D will be populated With either Dual SFP Giga or Dual RJ-45 Gigabit, or combo of both.
Page 25
Installation and User Guide (10/07) Applications Magnum 6K25e Fiber Switches offer high performance and modularity. They provide the flexibility of 100Mbps fiber and copper ports as well as Gigabit ports, with industry-standard LAN management software. Magnum 6K25e Switches are easily used...
Page 26
The Magnum 625e Managed Switch equipped with copper and optional dual Gigabit fiber ports on modular slots provide an economical and seamless solution to the requirements. The user-configurable Magnum 6K25e provides an extra boost to the network requirements by providing copper/fiber media along with the higher bandwidth 10/ 1 00 support of 10/100 and 1000Mb.
The versatile mechanical design with rack mounting capability and AC/DC option will be an additional feature to take care of temperature and power option issue. Equipped with IGMP-L2 mode enhanced features allow the Magnum 6K25e to meet the fastest growing application of video monitoring or video surveillance demand of industry and provide an economical and effective solution to meet that expectation.
Locate an AC receptacle that is within six feet (2 meters) of the intended Magnum 6K25e site. The rugged metal case of the Magnum 6K25e will normally protect it from accidental damage in a lab or workplace setting. Maintain an open view of the front to visually monitor the status LEDs.
3.2.4 Connecting Twisted Pair (RJ-45,CAT3, CAT5, Unshielded or Shielded) The RJ-45 ports of the Magnum 6K25e can be connected to the following two media types: 100BASE-TX and 10BASE-T. CAT 5 cables should be used when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used.
3.2.5 Connecting Twisted Pair (CAT5E or better, Unshielded or Shielded) The RJ-45 Gigabit ports of the Magnum 6K25e can be connected to the media types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair (STP) balanced cable. The CAT 5E or better 100-ohm UTP or shielded twisted pair (STP) balanced cable is recommended to use when making 1000BASE-TX connections.
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) illuminated when the unit is powered and proper connection is established 3.2.6 Gigabit SFP (Small Form-factor Pluggable) Optical Transceivers The small form-factor pluggable (SFP) is a compact optical transceiver used in optical communications for both telecommunication and data communications applications.
Gb ZX, 1550nm wavelength, 70km distance Table-Top or Shelf Mounting The Magnum 6K25e Manageable Switches can be easily mounted on a table- top or any suitable horizontal surface, and has four rubber feet to provide stability without scratching finished surfaces.
The bracket mounting holes in the sides of the Magnum 6K25e permits it to be mounted in various ways. The same holes fit all three types (19”, ETSI, 23”) of brackets.
With each bracket type, there are three different mounting options is shown in Fig. 3.3.2. The case of the Magnum 6K25e has mounting holes prepared for each of the mounting arrangements. Users may choose the mounting arrangement most suitable for...
When this option is present, the terminal block for Alarm Contacts is part of the Power Input panel in the Magnum 6K25e case. The AC or DC power input connection is in the same panel. A manual On-Off Switch for power to the unit is not available on 6K25e units with the Alarm Contacts option, as these two features occupy the same space in the case.
Installation and User Guide (10/07) 6K25e Port Module (6KPM) Installation The Magnum 6K25e Switches are normally received from the factory with all required 6KPM modules installed. There may be situations where 6KPM cards need to be added or replaced. In cases where additional 6KPM cards are needed, the faceplate for an available front-mounted slot must be removed.
Page 37
Figure 3.5.1a: Removing Chassis Cover Caution: Be careful not to disturb the power supply. Looking down into the Magnum 6K25e unit, notice that there are individual PM installation spaces and female latch(white) connectors provided on the main board along with four stand-off’s for each 6KPM card position. (See Figure 3.5.1b).
Installation and User Guide (10/07) 3.5.2 Installing 6KPM Cards in the Magnum 6K25e Up to four front-mounted 6KPM cards may be installed in one Magnum 6K25e Managed Fiber Switch unit. Follow these steps to install a 6KPM. Step 1. Remove top chassis cover. See procedure in Section 3.5.1 above.
Page 39
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) Fig. 3.5.2c Daughter Board, top view of version for 4 copper 10/100 ports. Port# 1 Uplink Can be configured as uplink (x) crossed ports for cascading as shown in the Fig.
Page 40
Figure 3.5.2f: Securely latching up 6KPM Cards into a Magnum 6K25e NOTE: All 6KPM slots need not be filled in order for the Magnum 6K25e unit to be operational. When leaving 6KPM slots empty, always use a face plate (Magnum 6K8- BLNK) to cover the slot opening in the front panel.
Page 41
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) brackets and 6 #256 flat head screws. The brackets and screws have been installed inside of the top cover as shown in Fig. 3.5.2h. Fig. 3.5.2h Inside view of chassis cover (from the rear), showing the front panel screen plates installed inside the chassis cover using brackets and screws Step 8.
Console (DB-9) CONSOLE PORT Rear View of Magnum 6K25e, (Typical Console Port is on the Rear of Reverse 6K25e Models) Note: For detail description of Managed Network Software (MNS-6K) and Magnum 6K25e Switch configuration for Network Management, please refer to Magnum 6K25e Software Manual available on GarrettCom‘s FTP site.
Switching Functionality A Magnum 6K25e provides switched connectivity at Ethernet wire-speed among all of its ports. The Magnum 6K25e supports10/100Mbs for copper media and 10 or 100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and network performance. All ports can communicate to all other ports in a Magnum 6K25e, but local traffic on a port will not consume any of the bandwidth on any other port.
Address Learning All Magnum 6K25e units have address table capacities of 4K node addresses suitable for use in larger networks. They are self-learning, so as nodes are added, removed or moved from one segment to another, the 6K25e Switch automatically keeps up with node locations.
MNS software port settings and can check the port status of each port after the change. When Magnum 6K25e RJ-45 copper ports are set for auto-negotiation and are connected to another auto-negotiating device, there are 4 different speed and F/H modes possible depending on what the other device supports.
The Path Delay Value (PDV) bit-times must account for all devices and cable lengths within that domain. For Magnum 6K25e Fast Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.
Power Budget Calculations for Magnum 6K25e PM’s with Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget. To calculate the power budget of different fiber media...
The worst-case OPB of the fiber link must be greater than the fiber cable’s passive Attenuation. (Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor) Introduction - Magnum 6K25e Managed Fiber Switch Port Modules This chapter describes each Port Module (PM), including appearance, functionality, and status displays.
Refer to Chapter 5 for specific return procedures. 6KPM Module Description An important feature of the Magnum 6K25e is the use of Port Modules for flexible mixed-media connectivity to RJ-45 and fiber media. Since the Magnum 6K25e Switches have dual-speed capability for copper ports, the 6 or 8-port interfaces are designed to support all standard Ethernet media types at 10 or 100Mps speed.
100Mb combo module with the exception of 10Mb speed at the ST fiber module. The ST-connector functions as a fiber optic transceiver to support 10BASE-FX network segments. When installed in a Magnum 6K25e Managed Switch, the copper port supports the standard distance 100m on each port and the fiber port supports fiber optic cable distances up the IEEE-standard 10Mbps distance limits, i.e., typically 2km at full-...
10Mb fiber and 100Mb Full duplex for the 100Mb fiber. The 10Mb ST-fiber ports allow the user to connect their legacy 10Mb network to the Magnum 6K25e switch. They also provide a convenient way for the half duplex hub to connect to the switch through 10Mb...
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) fiber ports. Whereas the 100Mb ST module allow to connect the 100Mb demand of Switch devices. It supports distances according to the 10Base-FL standard i.e, 2Km distance for multi-mode fiber. (Single-mode for 10Km distance may be available as a special order).
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) The 6KP6-RJSSC, when installed in a Magnum 6K25e Switch operates on copper at the 100m distance. The Fiber is single-mode and cable lengths can be as much as 25+ Km (see Power Budget, Section 4.5)
100Mb full-duplex, whereas the bottom two ports multi-mode ST-Fiber support 10Mb half-duplex. This combo module provides more flexibility to the user to connect their legacy 10Mb fiber as well as 100Mb to the Magnum 6K25e Switch. When installed in a Magnum 6K25e Switch, the 100Mb MTRJ connector supports fiber optic cable distances up to the IEEE-standard 100Mbps distance limits, i.e., typically 2km at full-duplex and 412m at half-duplex.
“small-form-factor” used primarily in 100Mbps fiber-to-the-desktop links. When installed in a Magnum 6K25e Switch, it supports fiber optic cable distances up to the IEEE-standard 100Mbps distance limits, i.e., typically 2km at full-duplex and 412m at half-duplex.The compact size of the LC Connector reduces the size of wiring panels in wiring closets while providing the advantage of “future-proof”...
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) one housing that cannot be improperly inserted. Each port has an Activity (ACT) LED indicating packets being received, a Link (LK) LED indicating proper connectivity with the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off).
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) Crossover (MDI-X) switch, which controls all ports for cascaded connection. This feature eliminates the need for a special twisted pair crossover cable when connecting to a hub or another switch.
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) The LEDs on 6KP8-RJ45- PoE module are slightly different compared to regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the PoE LED is ON when connected properly to a 803.af compliant PD device on that port.
FULL/HALF six 10/100 RJ-45 ports and two 100Mb MTRJ fiber ports. When installed in a Magnum 6K25e Switch, it supports the standard distances as mentioned on 5.2.3. and the LEDs also act similarly. 5.2.12a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode...
ACTIVITY FULL/HALF 10/100 RJ-45 ports and 2 Single- mode fiber ports. When installed in a Magnum 6K25e Switch, it supports the standard distances as mentioned on 5.2.4. and the LEDs also act similarly. 5.2.13 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connector The Magnum GBIC-SXSC is a multi-mode Gigabit fiber connector equipped with SC type connectors and can be easily snapped in and out.
However, if you are unsure of the procedures described in this section or if the Magnum 6K25e Switch is not performing as expected, do not attempt to repair the unit; instead contact your supplier for assistance or contact GarrettCom Customer Support.
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) If the problem is isolated to a network device other than the Magnum 6K25e Switch product, it is recommended that the problem device be replaced with a known good device. Verify whether or not the problem is corrected. If not, go to Step 5 below.
Testing and repair of product that is not under warranty will result in a customer (user) charge. Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions: Package the unit carefully. It is recommended that you use the original container if available.
B3.0 APPLICATIONS FOR DC POWERED SWITCHES Magnum 6K25e Fiber Switches are easily installed in a variety of applications where -48VDC, 24VDC and 125VDC power is used as the primary power source. The- 48VDC, 24VDC and 125VDC power configuration provides an Ethernet networking solution utilizing a special power supply in a managed Fiber Switch.
Page 65
48V or –48V supply must be connected to the post labeled “+”. An ON-OFF manual switch is optional for DC power. This can be used to cut off power connections and as a RESET for the Magnum 6K25e Switch. www GarrettCom com...
4 inches apart, with the first one located within 6 inches of the terminal block. B5.0 OPERATION Operation of Magnum 6K25e Switches with the optional -48VDC, 24VDC and 125VDC power supply is identical to that of the standard AC-powered models. B6.0 ORDERING INFORMATION To order the optional -48VDC power supply factory installed, add a suffix of “-...
Page 67
Magnum 6K25e -48VDC, 24VDC and 125VDC models with this Dual-Source option are identical to those listed in the Magnum 6K25e Fiber Switches Installation and User Guide, including Appendix B “Internal DC Power Supply Option”...
Page 68
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) The -48VDC terminal block on the Magnum 6K25e Switch, as shown in Fig C5.0 is located on the right rear of the unit and A+ A- B- B+ is equipped with five (5) screw-down lead posts.
Page 69
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) Dual-Src24V for regular models with no ON-OFF switch Or Dual-Src125V-Switch for models with the ON-OFF switch C7.0 OPERATION Operation of the Dual-Source Magnum 6Ks-48VDC, 24VDC and 125VDC Switch models are identical to that of the standard models.