Class 2, or listed ITE Power Supply, marked LPS, which has suitably rated output voltage (i.e. 24VDC or 48VDC) and suitable rated output current. Product does not contain user replaceable fuses. Any internal fuses can ONLY be replaced by GarrettCom personnel through the RMA process. www GarrettCom com...
6KQE4-2MLC, 2 x LC / 2 x RJ45 (Slot C) ....... 34 5.1.9 6KQE4-3MLC, 3 x LC / 1 x RJ45 (Slot A, Slot C) ....34 5.1.10 6KQE4-xSLC, LC Singlemode (20km) / RJ45 Module .... 34 www GarrettCom com...
Page 5
Shipping and Packaging Information ..........39 APPENDIX A: WARRANTY INFORMATION ......... 39 APPENDIX B : DC Power Input ..............40 APPENDIX C: Internal DC Dual-Source Power Input Option ....43 Revisions: Rev. A 02/09: Initial Release www GarrettCom com...
- 20.0 km (66K ft) 100BASE-FX, full-duplex, Long Reach - 40.0 km (122K ft) Maximum Standard Gigabit Ethernet Segment Lengths: 1000BASE-T (CAT5e or higher is recommended) - 100m (328 ft) 1000BASE-SX, full-duplex, multi-mode (62.5μm cable) - 220m www GarrettCom com...
24VDC Power Input nominal (range 18 to 36VDC) -48VDC Power Input nominal (range 36 to 60VDC) 125VDC Power Input nominal (range 88 to 150VDC) 250VDC Power Input nominal (range 160 to 300VDC) Std. Terminal Block : “ -, GND, + ” www GarrettCom com...
Page 8
Class1 Division 2 and ATEX for hazardous locations, pending Warranty: Three years, per UL 60950 temperature rating Made in USA See the Configuration Guide on the GCI web site at http://www.garrettcom.com/techsupport/insertion_guides/6kqecg.pdf for configurations and options.. info@GarrettCom.com Email for additional information. www GarrettCom com...
10/100 copper and one SM 40Km 100Mb LC fiber ports 6KQF-2SLCL adds two 10/100 copper and two SM 40Km 100Mb LC fiber ports 6KQF-3SLCL adds one 10/100 copper and three SM 40Km 100Mb LC fiber ports MM= Multi-mode fiber SM= Single-mode fiber www GarrettCom com...
Page 10
CONFORM05 CRM: Conformal coating, heavy duty silicone at 5 mil thickness, for interior PCBs, PS and modules (for moisture protection) CONFORM14 CRM: Conformal coating, heavy duty silicone at 14 mil thickness, for interior PCBs, PS and modules (for oil and gas industry) www GarrettCom com...
In the event there are items missing or damaged, contact the party from whom you purchased the product. If the unit needs to be returned, please use the original shipping container if possible. Refer to Section 6, Troubleshooting, for specific return procedures. www GarrettCom com...
Component Parts method, or -40˚C to 85˚C by the IEC 60068 Type-Test method. With options such as several popular DC power input types, AC power and DIN-Rail mounting, the hardened Magnum 6KQE is a “multi-purpose” Industrial Ethernet Switch. www GarrettCom com...
802.1p standard. In addition to hardware support for QOS, the MNS software (R2) supports two priority queues that can be shared across the eight levels of defined packet priorities for application-specific priority control by the user through software configuration settings. www GarrettCom com...
(when operating at half-duplex only). When the Switch detects that its free buffer queue space is low, the Switch prevents more frames from entering by forcing a collision signal on all receiving half-duplex ports in order to stop incoming traffic. www GarrettCom com...
: m6kuser password : m6kuser All MNS-6K software information, and the documentation related to MNS-6K and MNS- 6K-SECURE software, can be accessed at GarrettCom’s FTP site. Alternatively, for the latest documentation and information, or needed GarrettCom’s MIBs for SNMP, visit www.GarrettCom.com/techsupport/index.htm#software...
MNS-6K-SECURE (optional, for extra security) Magnum MNS-6K-SECURE software is designed for those customers demanding extra security in their networks. MNS-6K-SECURE is an optional item--licensed per switch. All of the features in regular MNS-6K are included, plus extra security. www GarrettCom com...
100Mbps or 10 Mbps speed, and full-or half-duplex. The mixed-media modular capability is ideal for industrial applications where existing Ethernet LAN network cabling must be accommodated. The fiber-built-in media capability is ideal for integrating future-proof fiber cabling into the LAN structure. www GarrettCom com...
Page 18
Fiber ports supported by the Magnum 6KQE Switch. A main NT-server in a secure area protected from earthquake or fire hazards can be connected to the full duplex Gigabit Fiber port. Fig 2.5a The industrial factory floor application with Magnum 6KQE www GarrettCom com...
Page 19
Magnum 6KQE provides an extra boost to the network requirements by providing copper/fiber media along with the higher bandwidth support of 10/100 and 1000Mb. The user can utilize the SNMP feature equipped with VLAN, RMON, STP and www GarrettCom com...
Page 20
The Gigabit uplink for storage or broadband uplink allows the telecom user a very effective solution to store their sensitive data securely. Fig 2.5c Magnum 6KQE deployed in a video security CCTV application for monitoring and securing the premises www GarrettCom com...
The 6KQE has no fans, so it is silent when in operation. Internal electronics use the case as a heat sink, so the unit may normally be quite warm to the touch. www GarrettCom com...
Connect the other end of the cable to the corresponding device Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established. www GarrettCom com...
(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are the diameters of the core and the core plus the cladding respectively). Single-mode fiber allows full bandwidth at longer distances, about 70km with the single-mode LC. www GarrettCom com...
Make certain the connectors are clean before connecting. Note: One strand of the duplex fiber optic cable is coded using color bands at regular intervals; you must use the color-coded strand on the associated ports at each end of the fiber optic segment. www GarrettCom com...
Since the 6KQE has special internal thermal techniques (patent pending) to move the heat generated by the electronic components inside into the case, the case may be quite warm to the touch during normal operation. www GarrettCom com...
6KQE for DIN-Rail mounting purposes. The required four screws are included with the DIN-Rail bracket, and are no.4-40 X 5/16 PHIL. PAN Head. To install the 6KQE with the DIN-Rail bracket installed, hold the 6KQE in the side www GarrettCom com...
* 12VDC, -48VDC, 24VDC, 125VDC and 250VDC with single DC input, * 12VDC, -48VDC, 24VDC, 125VDC and 250VDC with dual-source DC input * AC input with internal power supply (see Section 1.2, for Ordering Information) www GarrettCom com...
The Alarm Contacts are on the front left area (next to the DC power source) of the Magnum 6KQE unit and are green in color as shown in the picture. Fig 3.5a Alarm Contacts: (1,2) are hardware operated (3,4) are software operated www GarrettCom com...
Note: The DB-9 cable is not included with the 6KQE package. Note: For a detailed description of Managed Network Software (MNS-6K) and Magnum 6KQE Switch configuration for Network Management, please refer to Magnum 6K Software Manual available on GarrettCom‘s FTP site. Also available on GCI website at: http://www.garrettcom.com/techsupport/sw_downloads.htm 3.6.1...
6KQE Switch automatically keeps up with node locations. An address-aging algorithm causes least-used addresses to fall out in favor for frequently-used addresses. To reset the address buffer, cycle power down-and-up. www GarrettCom com...
Auto-negotiation per-port for 802.3u-compliant switches occurs when: -- the devices at both ends of the cable are capable of operation at either 10Mb or 100Mb speed and/or in full- or half-duplex mode, and can send/receive auto-negotiation pulses, and . . . www GarrettCom com...
10/100 Mb ports for flow control. That is, the switch prevents frames from entering the device by forcing a collision indication on the half-duplex ports that are receiving. This temporary “collision” delay allows the available buffer space to improve as the switch catches up with the traffic flow. www GarrettCom com...
6K products such as the 6K25e and 6K16V. For information about other 6K products, please see the applicable manual. For a list of 6KQE Port Modules, refer to Section 1.2 Each 6KQE Port Module (PM) is individually described in the following sections. www GarrettCom com...
Gigabit (Copper / Fiber) 1= ON (Full Dx), OFF (Half Dx) 2= ON (Link) 3= BLINKING (Activity) 4= ON (1000Mb) Not used for Fiber 5= ON (100Mb) Not used for Fiber 6= ON (10Mb) Not used for Fiber www GarrettCom com...
N-way auto-negotiating and auto-crossover (MDIX) for operation at 10 or 100Mb speed in full- or half-duplex mode. (i.e., each independently selects a mode and speed to match the device at the other end of the twisted pair cable). www GarrettCom com...
Multimode connector. The MTRJ’s small size and ease of connection make it a good choice for 100Mbps “fiber-to-the-desktop” Ethernet connectivity. When installed in a Magnum 6KQE Series Switch, it supports fiber optic cable distances up to the IEEE- www GarrettCom com...
The 6KQE4-3MMRJ 4-port Fiber / Copper module provides three 100Mb Multimode MTRJ Fiber ports and one 10/100Mb switched RJ-45 port. This module option occupies parts of Slot “A” and Slot “C”. (see also Section 5.1.4 for information) www GarrettCom com...
(UTP) and shielded twisted pair (STP) cable connections. When installed in a Magnum 6KQE Series Managed Switch, the copper ports support the standard distance of 100m on each port. www GarrettCom com...
The 6KQF-xSLCL 4-port Fiber / Copper modules provide 100Mb Singlemode LC Fiber ports, supporting distances up to 40km , and 10/100Mb switched RJ45 ports. These modules provide the same functions as the Multimode versions (see Sections 5.1.7 thru 5.1.9 for more detail and panel configurations). www GarrettCom com...
The 6KQE-1GCU 1-port Copper Gigabit module provides one fixed 10/100/1000Mb RJ-45 port. 5.1.13 6KQE-2GSFP, 1GSFP (Gigabit SFP Fiber ports) (Slot D) The 6KQE-2GSFP 2-port Fiber Gigabit module provides two SFP open transceiver locations that can operate at 10/100/1000Mbps speeds. Transceivers are www GarrettCom com...
48VDC power input source to the Magnum 6KQE must be strong enough to provide power to the 6K switch and to all 4-RJ-45 ports with PD devices connected (up to 15 watts per PoE port). www GarrettCom com...
If the problem continues after completing Step 4 above, contact your supplier of the Magnum 6KQE Switch unit or if unknown, contact GarrettCom, Inc. by fax, phone or email (support@garrettcom.com) for assistance. When Calling for Assistance Please be prepared to provide the following information.
Date of installation Failure symptoms, including a full description of the problem. GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details).
GarrettCom. This warranty will not be effective if, in the opinion of GarrettCom, the product has been damaged by misuse, misapplication, or as a result of service or modification other than by GarrettCom.
This allows the Switch to operate only whenever DC power is correctly applied to the two inputs. It protects the Switch from incorrect DC input connections. An incorrect polarity www GarrettCom com...
Page 46
+ve potential lead or -ve potential lead. The more +ve potential lead will connect to the post labeled “+ve” and the rest to the “-ve”. The GND can be hooked up at the last www GarrettCom com...
Page 47
OPERATION Operation of Magnum 6KQE Switches with the optional -48VDC, 12VDC, 24VDC, 125VDC or 250VDC dual-source power input is identical to that of the standard single-source DC-powered models. B6.0 TROUBLESHOOTING Please refer to Section 6.0 for troubleshooting www GarrettCom com...
The functionality of the Magnum 6KQE Switch -48VDC, 12VDC, 24VDC, 125VDC and 250VDC Dual-Source Option units are identical to the AC-powered models. Refer to the main sections of this Installation and User Guide for a detailed description of the Magnum 6KQE Switches. www GarrettCom com...
Page 49
Dual Source Terminal block C5.0 INSTALLATION This section describes the proper connection of the -48VDC, 12VDC, 24VDC, 125VDC and 250VDC dual source leads to the power terminal block on the Magnum 6KQE Switch (shown in Figure above) www GarrettCom com...
Page 50
To order the optional Dual-Source power supply factory installed, add “Dual- Src-xxxV” as a separate line item following the product model. Example: Magnum 6KQE-48VDC Dual-Src-48V See the Configuration Guide on the GCI web site at http://www.garrettcom.com/techsupport/insertion_guides/6kqecg.pdf for additional information. www GarrettCom com...
Need help?
Do you have a question about the Magnum 6KQE and is the answer not in the manual?
Questions and answers