GarrettCom Magnum 6KQE Installation And User Manual

GarrettCom Magnum 6KQE Installation And User Manual

Managed edge switch
Table of Contents

Advertisement

Magnum 6KQE
Managed Edge Switch
Hardware
Installation and User Guide
www GarrettCom com
.
.
$5.00 USD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Magnum 6KQE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GarrettCom Magnum 6KQE

  • Page 1 Magnum 6KQE Managed Edge Switch Hardware Installation and User Guide www GarrettCom com $5.00 USD...
  • Page 2 If problems are experienced with Magnum 6KQE Switch products, consult Section 6, Trouble Shooting. Copyright © 2009 GarrettCom, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from GarrettCom, Inc.
  • Page 3 Class 2, or listed ITE Power Supply, marked LPS, which has suitably rated output voltage (i.e. 24VDC or 48VDC) and suitable rated output current. Product does not contain user replaceable fuses. Any internal fuses can ONLY be replaced by GarrettCom personnel through the RMA process. www GarrettCom com...
  • Page 4: Table Of Contents

    6KQE4-2MLC, 2 x LC / 2 x RJ45 (Slot C) ....... 34     5.1.9 6KQE4-3MLC, 3 x LC / 1 x RJ45 (Slot A, Slot C) ....34     5.1.10 6KQE4-xSLC, LC Singlemode (20km) / RJ45 Module .... 34 www GarrettCom com...
  • Page 5 Shipping and Packaging Information ..........39   APPENDIX A: WARRANTY INFORMATION ......... 39   APPENDIX B : DC Power Input ..............40   APPENDIX C: Internal DC Dual-Source Power Input Option ....43 Revisions: Rev. A 02/09: Initial Release www GarrettCom com...
  • Page 6: Specifications

    - 20.0 km (66K ft) 100BASE-FX, full-duplex, Long Reach - 40.0 km (122K ft) Maximum Standard Gigabit Ethernet Segment Lengths: 1000BASE-T (CAT5e or higher is recommended) - 100m (328 ft) 1000BASE-SX, full-duplex, multi-mode (62.5μm cable) - 220m www GarrettCom com...
  • Page 7: Magnum 6Kqe Managed Edge Switch Installation And User Guide

    24VDC Power Input nominal (range 18 to 36VDC) -48VDC Power Input nominal (range 36 to 60VDC) 125VDC Power Input nominal (range 88 to 150VDC) 250VDC Power Input nominal (range 160 to 300VDC) Std. Terminal Block : “ -, GND, + ” www GarrettCom com...
  • Page 8 Class1 Division 2 and ATEX for hazardous locations, pending Warranty: Three years, per UL 60950 temperature rating Made in USA See the Configuration Guide on the GCI web site at http://www.garrettcom.com/techsupport/insertion_guides/6kqecg.pdf for configurations and options.. info@GarrettCom.com Email for additional information. www GarrettCom com...
  • Page 9: Ordering Information

    10/100 copper and one SM 40Km 100Mb LC fiber ports 6KQF-2SLCL adds two 10/100 copper and two SM 40Km 100Mb LC fiber ports 6KQF-3SLCL adds one 10/100 copper and three SM 40Km 100Mb LC fiber ports MM= Multi-mode fiber SM= Single-mode fiber www GarrettCom com...
  • Page 10 CONFORM05 CRM: Conformal coating, heavy duty silicone at 5 mil thickness, for interior PCBs, PS and modules (for moisture protection) CONFORM14 CRM: Conformal coating, heavy duty silicone at 14 mil thickness, for interior PCBs, PS and modules (for oil and gas industry) www GarrettCom com...
  • Page 11: Introduction

    In the event there are items missing or damaged, contact the party from whom you purchased the product. If the unit needs to be returned, please use the original shipping container if possible. Refer to Section 6, Troubleshooting, for specific return procedures. www GarrettCom com...
  • Page 12: Product Description - Magnum 6Kqe Managed Edge Switch

    Component Parts method, or -40˚C to 85˚C by the IEC 60068 Type-Test method. With options such as several popular DC power input types, AC power and DIN-Rail mounting, the hardened Magnum 6KQE is a “multi-purpose” Industrial Ethernet Switch. www GarrettCom com...
  • Page 13: Packet Prioritization, 802.1P Qos

    802.1p standard. In addition to hardware support for QOS, the MNS software (R2) supports two priority queues that can be shared across the eight levels of defined packet priorities for application-specific priority control by the user through software configuration settings. www GarrettCom com...
  • Page 14: Frame Buffering And Flow Control

    (when operating at half-duplex only). When the Switch detects that its free buffer queue space is low, the Switch prevents more frames from entering by forcing a collision signal on all receiving half-duplex ports in order to stop incoming traffic. www GarrettCom com...
  • Page 15: Managed Network Software For Magnum 6Kqe

    : m6kuser password : m6kuser All MNS-6K software information, and the documentation related to MNS-6K and MNS- 6K-SECURE software, can be accessed at GarrettCom’s FTP site. Alternatively, for the latest documentation and information, or needed GarrettCom’s MIBs for SNMP, visit www.GarrettCom.com/techsupport/index.htm#software...
  • Page 16: Features And Benefits

    MNS-6K-SECURE (optional, for extra security) Magnum MNS-6K-SECURE software is designed for those customers demanding extra security in their networks. MNS-6K-SECURE is an optional item--licensed per switch. All of the features in regular MNS-6K are included, plus extra security. www GarrettCom com...
  • Page 17: Applications

    100Mbps or 10 Mbps speed, and full-or half-duplex. The mixed-media modular capability is ideal for industrial applications where existing Ethernet LAN network cabling must be accommodated. The fiber-built-in media capability is ideal for integrating future-proof fiber cabling into the LAN structure. www GarrettCom com...
  • Page 18 Fiber ports supported by the Magnum 6KQE Switch. A main NT-server in a secure area protected from earthquake or fire hazards can be connected to the full duplex Gigabit Fiber port. Fig 2.5a The industrial factory floor application with Magnum 6KQE www GarrettCom com...
  • Page 19 Magnum 6KQE provides an extra boost to the network requirements by providing copper/fiber media along with the higher bandwidth support of 10/100 and 1000Mb. The user can utilize the SNMP feature equipped with VLAN, RMON, STP and www GarrettCom com...
  • Page 20 The Gigabit uplink for storage or broadband uplink allows the telecom user a very effective solution to store their sensitive data securely. Fig 2.5c Magnum 6KQE deployed in a video security CCTV application for monitoring and securing the premises www GarrettCom com...
  • Page 21: Installation

    The 6KQE has no fans, so it is silent when in operation. Internal electronics use the case as a heat sink, so the unit may normally be quite warm to the touch. www GarrettCom com...
  • Page 22: Connecting Ethernet Media

    Connect the other end of the cable to the corresponding device Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established. www GarrettCom com...
  • Page 23: Connecting Twisted Pair (Cat5E Or Better, Utp Or Stp)

    (9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are the diameters of the core and the core plus the cladding respectively). Single-mode fiber allows full bandwidth at longer distances, about 70km with the single-mode LC. www GarrettCom com...
  • Page 24: Gigabit Sfp (Small Form-Factor Pluggable) Transceivers

    Make certain the connectors are clean before connecting. Note: One strand of the duplex fiber optic cable is coded using color bands at regular intervals; you must use the color-coded strand on the associated ports at each end of the fiber optic segment. www GarrettCom com...
  • Page 25: Mounting Dimensions For 6Kqe With Metal Brackets

    Since the 6KQE has special internal thermal techniques (patent pending) to move the heat generated by the electronic components inside into the case, the case may be quite warm to the touch during normal operation. www GarrettCom com...
  • Page 26: Din-Rail Mounting The Magnum 6Kqe

    6KQE for DIN-Rail mounting purposes. The required four screws are included with the DIN-Rail bracket, and are no.4-40 X 5/16 PHIL. PAN Head. To install the 6KQE with the DIN-Rail bracket installed, hold the 6KQE in the side www GarrettCom com...
  • Page 27: Powering The Magnum 6Kqe Managed Edge Switch

    * 12VDC, -48VDC, 24VDC, 125VDC and 250VDC with single DC input, * 12VDC, -48VDC, 24VDC, 125VDC and 250VDC with dual-source DC input * AC input with internal power supply (see Section 1.2, for Ordering Information) www GarrettCom com...
  • Page 28: Alarm Contacts For Monitoring Internal Power, And Software Traps

    The Alarm Contacts are on the front left area (next to the DC power source) of the Magnum 6KQE unit and are green in color as shown in the picture. Fig 3.5a Alarm Contacts: (1,2) are hardware operated (3,4) are software operated www GarrettCom com...
  • Page 29: Connecting The Console Terminal To Magnum 6Kqe

    Note: The DB-9 cable is not included with the 6KQE package. Note: For a detailed description of Managed Network Software (MNS-6K) and Magnum 6KQE Switch configuration for Network Management, please refer to Magnum 6K Software Manual available on GarrettCom‘s FTP site. Also available on GCI website at: http://www.garrettcom.com/techsupport/sw_downloads.htm 3.6.1...
  • Page 30: Operation

    6KQE Switch automatically keeps up with node locations. An address-aging algorithm causes least-used addresses to fall out in favor for frequently-used addresses. To reset the address buffer, cycle power down-and-up. www GarrettCom com...
  • Page 31: Auto-Cross(Mdix) And Auto-Negotiation, For Rj-45 Ports

    Auto-negotiation per-port for 802.3u-compliant switches occurs when: -- the devices at both ends of the cable are capable of operation at either 10Mb or 100Mb speed and/or in full- or half-duplex mode, and can send/receive auto-negotiation pulses, and . . . www GarrettCom com...
  • Page 32: Flow-Control, Ieee 802.3X Standard

    10/100 Mb ports for flow control. That is, the switch prevents frames from entering the device by forcing a collision indication on the half-duplex ports that are receiving. This temporary “collision” delay allows the available buffer space to improve as the switch catches up with the traffic flow. www GarrettCom com...
  • Page 33: Power Budget Calculations For 6Kqe Modules With Fiber Media

    6K products such as the 6K25e and 6K16V. For information about other 6K products, please see the applicable manual. For a list of 6KQE Port Modules, refer to Section 1.2 Each 6KQE Port Module (PM) is individually described in the following sections. www GarrettCom com...
  • Page 34: 6Kqe Module Led Designations

    Gigabit (Copper / Fiber) 1= ON (Full Dx), OFF (Half Dx) 2= ON (Link) 3= BLINKING (Activity) 4= ON (1000Mb) Not used for Fiber 5= ON (100Mb) Not used for Fiber 6= ON (10Mb) Not used for Fiber www GarrettCom com...
  • Page 35: 6Kqe Base Unit Led Designations

    N-way auto-negotiating and auto-crossover (MDIX) for operation at 10 or 100Mb speed in full- or half-duplex mode. (i.e., each independently selects a mode and speed to match the device at the other end of the twisted pair cable). www GarrettCom com...
  • Page 36: 6Kqe4-1Mmrj, 1 X Mtrj / 3 X Rj45 (Slot C)

    Multimode connector. The MTRJ’s small size and ease of connection make it a good choice for 100Mbps “fiber-to-the-desktop” Ethernet connectivity. When installed in a Magnum 6KQE Series Switch, it supports fiber optic cable distances up to the IEEE- www GarrettCom com...
  • Page 37: 6Kqe4-2Mmrj, 2 X Mtrj / 2 X Rj45 (Slot C)

    The 6KQE4-3MMRJ 4-port Fiber / Copper module provides three 100Mb Multimode MTRJ Fiber ports and one 10/100Mb switched RJ-45 port. This module option occupies parts of Slot “A” and Slot “C”. (see also Section 5.1.4 for information) www GarrettCom com...
  • Page 38: 6Kqe4-1Mlc, 1 X Lc / 3 X Rj45 (Slot C)

    (UTP) and shielded twisted pair (STP) cable connections. When installed in a Magnum 6KQE Series Managed Switch, the copper ports support the standard distance of 100m on each port. www GarrettCom com...
  • Page 39: 6Kqe4-2Mlc, 2 X Lc / 2 X Rj45 (Slot C)

    The 6KQF-xSLCL 4-port Fiber / Copper modules provide 100Mb Singlemode LC Fiber ports, supporting distances up to 40km , and 10/100Mb switched RJ45 ports. These modules provide the same functions as the Multimode versions (see Sections 5.1.7 thru 5.1.9 for more detail and panel configurations). www GarrettCom com...
  • Page 40: 6Kqe-2Gcu, 1Gcu (Gigabit Rj45 Copper Ports) (Slot D)

    The 6KQE-1GCU 1-port Copper Gigabit module provides one fixed 10/100/1000Mb RJ-45 port. 5.1.13 6KQE-2GSFP, 1GSFP (Gigabit SFP Fiber ports) (Slot D) The 6KQE-2GSFP 2-port Fiber Gigabit module provides two SFP open transceiver locations that can operate at 10/100/1000Mbps speeds. Transceivers are www GarrettCom com...
  • Page 41: 6Kqep-48Vdc, Base Unit W/Poe Power-Pass-Through

    48VDC power input source to the Magnum 6KQE must be strong enough to provide power to the 6K switch and to all 4-RJ-45 ports with PD devices connected (up to 15 watts per PoE port). www GarrettCom com...
  • Page 42: Troubleshooting

    If the problem continues after completing Step 4 above, contact your supplier of the Magnum 6KQE Switch unit or if unknown, contact GarrettCom, Inc. by fax, phone or email (support@garrettcom.com) for assistance. When Calling for Assistance Please be prepared to provide the following information.
  • Page 43: Return Material Authorization (Rma) Procedure

    Date of installation Failure symptoms, including a full description of the problem. GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details).
  • Page 44: Shipping And Packaging Information

    GarrettCom. This warranty will not be effective if, in the opinion of GarrettCom, the product has been damaged by misuse, misapplication, or as a result of service or modification other than by GarrettCom.
  • Page 45: Appendix B : Dc Power Input

    This allows the Switch to operate only whenever DC power is correctly applied to the two inputs. It protects the Switch from incorrect DC input connections. An incorrect polarity www GarrettCom com...
  • Page 46 +ve potential lead or -ve potential lead. The more +ve potential lead will connect to the post labeled “+ve” and the rest to the “-ve”. The GND can be hooked up at the last www GarrettCom com...
  • Page 47 OPERATION Operation of Magnum 6KQE Switches with the optional -48VDC, 12VDC, 24VDC, 125VDC or 250VDC dual-source power input is identical to that of the standard single-source DC-powered models. B6.0 TROUBLESHOOTING Please refer to Section 6.0 for troubleshooting www GarrettCom com...
  • Page 48: Appendix C: Internal Dc Dual-Source Power Input Option

    The functionality of the Magnum 6KQE Switch -48VDC, 12VDC, 24VDC, 125VDC and 250VDC Dual-Source Option units are identical to the AC-powered models. Refer to the main sections of this Installation and User Guide for a detailed description of the Magnum 6KQE Switches. www GarrettCom com...
  • Page 49 Dual Source Terminal block C5.0 INSTALLATION This section describes the proper connection of the -48VDC, 12VDC, 24VDC, 125VDC and 250VDC dual source leads to the power terminal block on the Magnum 6KQE Switch (shown in Figure above) www GarrettCom com...
  • Page 50 To order the optional Dual-Source power supply factory installed, add “Dual- Src-xxxV” as a separate line item following the product model. Example: Magnum 6KQE-48VDC Dual-Src-48V See the Configuration Guide on the GCI web site at http://www.garrettcom.com/techsupport/insertion_guides/6kqecg.pdf for additional information. www GarrettCom com...