Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (07/10)
24VDC Power Input Voltage : 20 to 40VDC
Fuse Required – 3 Amps
125VDC and 100VDC Input Voltage : 88 to 300VDC
Fuse Required – 1 Amp
Std. Terminal Block : " -, GND, + "
Power Consumption: same as for AC models, see above
Warning- All the fuse replacement must be replaced with same value.
For (Optional) DC internal power supplies at –48VDC, 24VDC and 125VDC,
including Dual Source options (
input sources are interrupted)
Cooling Method-
6K32F/ 6K32FR(Reverse)- Fan cooled (3 fans inside)
6K32FC / 6K32FRC(Reverse)- Convection cooled (No fans) Static Thermal
Relay Alarm Contact (Optional)
The Alarm Contact option is offered as a configuration option. The alarms can be
initiated through two normally closed Form-C contacts, one loss of power alarm
and one software alarm through user selectable software traps.
Per-port MDI or MDIX on RJ-45
The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45
ports which eliminates the use of cross-over cable between the devices. Also
port-specific user settings (such as FDX or HDX, copper 10/100 speed) can
be fixed using software commands.
Agency Approvals
UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15, Class A
NEBS L3 and ETSI Compliant, NEMA TS-2 for traffic control
IEEE 1613 Classs 2 Environmental Standard for Electric Power Substations.
See also Note for Power Substations in Section 3.2.4, 3.6.1, and 5.2.9
IEC61850 EMC and Operating Conditions Class C for Power Substations
Warranty: Three years, return to factory
For a Configuration Guide, see the GarrettCom web site at
http://www.garrettcom.com/techsupport/insertion_guides/6k32fcg.pdf
(6K32F / FR)
http://www.garrettcom.com/techsupport/insertion_guides/6k32fccg.pdf
(6K32FC / FRC)
mktg@GarrettCom.com
Email
www GarrettCom com
.
for continuity of operation when either of the DC
, see Appendices B and C.
for additional details.
.
design techniques
3
Made in USA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnum 6k32fcMagnum 6k32frcMagnum 6k32fr

Table of Contents