Trace data communication number
Communication
No.
E000
E100
E199
E200
E299
E300
E399
E400
E499
Ex.) When operation frequency data is acquired through a communication device
Data acquired () h=8000 ⇒ 8000×0.01Hz=80.0Hz
Relationship between pointer and data
The table below shows the relationship between pointer (E000 set value) and trace data (1 to 4).
Pointer (E000 set value)
Trace data 1 ( E100 ∼ E199 )
Trace data 2 ( E200 ∼ E299 )
Trace data 3 ( E300 ∼ E399 )
6
Trace data 4 ( E400 ∼ E499 )
<Example of setting> If E000 is set to :
Trace data 1
Trace data 2
Trace data 3
Trace data 4
Note 1: Use the parameters  through to specify the types of trace data (1 to 4).
Note 2: Communication numbers E000 is automatically incremented by the inverter when data is traced
6.33

Integrating wattmeter

 : Integrating wattmeter retention selection
 : Integrating wattmeter display unit selection
• Function
At the main power off ,it is selectable whether retention of integral output power values or not.
And also, the display unit is selectable.
The integrating wattmeter display can be cleared by external input signal by assignment of the terminal
function. Input terminal function 74, 75 (Integrating wattmeter display clear)
Title


Function
Trace data 1~4 pointer
Data 1 of trace data 1
Data 2~99 of trace data 1
Data 100 of trace data 1
Data 1 of trace data 2
Data 2~99 of trace data 2
Data 100 of trace data 2
Data 1 of trace data 3
Data 2~99 of trace data 3
Data 100 of trace data 3
Data 1 of trace data 4
Data 2~99 of trace data 4
Data 100 of trace data 4
(Earliest data)
E102   ~   E199, E100, E101
E202   ~   E299, E200, E201
E302   ~   E399, E300, E301
E402   ~   E499, E400, E401
continuously.
* In ordinary cases, these parameters do not need to be rewritten.
Function
Integrating wattmeter retention selection
Integrating wattmeter display unit selection
Minimum setting
Setting/readout range
/readout unit
/
~
/
~
/
~
/
~
/
~
/
~
/
~
/
~
/
~
/
~
/
~
/
~
/
~
E100
E101
E102
E200
E201
E202
E300
E301
E302
E400
E401
E402
(Latest data)
Adjustment range
: Disabled
: Enabled
: 1 = 1 kWh
: 1 = 10 kWh
: 1 = 100 kWh
: 1 = 1000 kWh
: 1 = 10000 kWh
F-70
E6581386
Default setting
~


~
E198
E199
~
E298
E299
~
E398
E399
~
E498
E499
Default setting
Accoding to
model
⇒ Refer to
page K-41.