Local/remote key function (=)
With this function, the means of starting and stopping operation and setting frequencies can be switched easily
between the operation panel and the means selected with the parameters (command mode selection) and
(frequency setting mode selection).
To switch between them, set the parameter to and use the EASY key.
Local mode: When Local mode selected by
EASY
Remote mode : Start and stop, and frequency setting follow the selection of (Command
Setting mode – Switching of commands and references
Commands
Terminal board
Operation panel
RS485
communication
Communication
option
References
Terminal board
(VI/II,RR,RX)
Operation panel
RS485
communication
Communication
option
UP/DOWN
Optional
Terminal board
(VI/II,RR,RX)
Operation panel
RS485
communication
Communication
option
UP/DOWN
Optional
effective only by operation panel keys.
The EASY key lamp is lit while Local mode selected.
mode),or (Frequency setting mode).
Local/Remote
Operation panel
Logic input: 104
Frequency reference
priority switching
Operation
panel
References
E-45
EASY
key, start and stop, and frequency setting are
Key
EASY
Logic input: 108
Command terminal
board priority
Terminal
board
Serial communication
Logic input: 106
VI/II terminal priority
VI/II
Serial communication
E6581386
Logic input: 48
Communication
priority cancel
Run / Forward
Run / Reverse
Internal
reference