Toshiba VF-PS1 Instruction Manual page 123

Variable torque inverter
Hide thumbs Also See for VF-PS1:
Table of Contents

Advertisement

2) Automatic switching by means of switching frequencies (=)
Command selected
with 
Command selected
with 
A: If the frequency set with  is higher than that set with  ・・・・・・・・・・・・・・ Priority is given to the
B: If the frequency set with  is equal to or lower than that set with  ・・・・・ Priority is given to the
Frequency setting signal
[ Parameter setting]
Title
Frequency setting mode selection 1

Frequency priority selection

Frequency setting mode selection 2

Speed command priority switching

frequency
A
B


Priority is given to
the command set
with .
Function
:VI/II (voltage/current input)
:RR/S4 (potentiometer/voltage input)
:RX (voltage input)
:Operation panel input enabled
:2-wire RS485 communication input
:4-wire RS485 communication input
:Communications option input
:Optional AI1 (differential current input)
:Optional AI2 (voltage/current input)
:Up/Down frequency
:Optional RP pulse input
:Optional high-speed pulse input
:/ terminal switching
(input terminal function selection ,
)
:/ frequency switching
(switching with )
Same as  (~)
~ Hz
F-11
Operation frequency
command
command set with .
command set with .

Priority is given to
the command set
with .
Adjustment range
(including LED/LCD option input)
E6581386
6
Default setting


Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents