List Of Parameters - Pfaff 8390 Instruction Manual

Table of Contents

Advertisement

Adjustment
13

List of parameters

.14.02
108
Only appropriately trained personnel is authorized to alter the set values
in the parameters!
SeqCont
0:
Process sequence program as quick key selection.
1:
Sequence programs are automatically relayed.
Y1mode
0: lp
1: hp
Manprog
0:
Manual data records cannot be saved or loaded.
1:
Manual data records can be saved and loaded as
programs in area 130..149.
Diffmode
0:
Foot switch (3 stage, 2 stage) is used as a switch
pedal during the sealing process for reducing and
increasing speed.
1:
Foot switch is used only for differential correction.
VQLIM
if positive: error #17 boundary stress
if negative: max. stress at standstill
Slowspeed
Switching speed * 0.1 m/min
Speedred
Reduction (or increase) of carriage speed when
sealing with double foot switch in %
PWRtest
Experimental display of energy input when sealing
0: off; 1: on
POS1speed
The input value determines the reduced speed of
treadle level +1 as a percentage value of the current
welding speed
HEATOUT-
The input value determines the tilt out time of the
DELAY
heating element as a percentage value of the cur-
rent braking range.
0 - 1
1
0 - 1
1
0 - 1
0
0 - 1
0
+/- 2400
500
10 - 55
15
10 - 99
90
0 - 1
0
10 - 100
100
0 - 300
0